Related Experiment Video
Updated: Mar 3, 2026

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Lifebox pulse oximeter implementation in Malawi: evaluation of educational outcomes and impact on oxygen desaturation
V Albert1, S Mndolo2, E M Harrison3
1Broomfield Hospital, Chelmsford, UK.
Abstract:
Pulse oximetry is an essential monitor for safe anaesthesia but is often not available in low-income countries. The aim of this study was to determine whether the introduction of pulse oximetry with training was feasible and could reduce the incidence of oxygen desaturation during anaesthesia in a low-income country. Pulse oximeters were donated, with training, to 83 non-physician anaesthetists in Malawi. Knowledge was tested immediately before and after training and at follow-up. Providers were asked to record the lowest peripheral oxygen saturation (SpO2 ) for the first 100 cases anaesthetised after training. The primary clinical outcome was the proportion of cases with an oxygen desaturation event (SpO2 < 90%). Seventy-seven of 83 (93%) participants completed all pre- and post-training tests. Pulse oximetry knowledge improved after training from a median (IQR [range]) score of 39 (37-42 [28-48]) to 44 (42-46 [35-50]) and this knowledge was maintained for 8 months (p < 0.001). Oxygen saturation data and provider responses were recorded for 4772 cases. The proportion of oxygen desaturation episodes decreased from 17.2% to 6.5%, representing a 36% reduction in the odds of an oxygen desaturation event in the second 50 cases compared with the first 50 (OR 0.64, 95%CI 0.50-0.82, p < 0.001). We conclude that donation of pulse oximeters, with training, in Malawi was feasible, improved knowledge and reduced the incidence of oxygen desaturation events.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...