Prediction of Both Electrical and Mechanical Reverse Remodeling on Acute Electrocardiogram Changes After Cardiac
Chien-Ming Cheng1,2, Chieh-Shou Su3,4, Pesus Chou2
1Division of Cardiology, Department of Medicine, Feng Yuan Hospital, Department of Health of the Executive Yuan.
Background:
The development of both electrical reverse remodeling and mechanical reverse remodeling (ERR+MRR) after cardiac resynchronization therapy (CRT) implantation could reduce the incidence of lethal arrhythmia, hence the prediction of ERR+MRR is clinically important.
Methods And Results:
Eighty-three patients (54 male; 67±12 years old) with CRT >6 months were enrolled. ERR was defined as baseline intrinsic QRS duration (iQRSd) shortening ≥10 ms in lead II on ECG after CRT, and MRR as improvement in LVEF ≥25% on echocardiography after CRT. Acute ECG changes were measured by comparing the pre-implant and immediate post-implant ECG. Ventricular arrhythmia episodes, including ventricular tachycardia and ventricular fibrillation, detected by the implanted device were recorded. Patients were classified as ERR only (n=12), MRR only (n=23), ERR+MRR (n=26), or non-responder (ERR- & MRR-, n=22). On multivariate regression analysis, difference between baseline intrinsic QRS and paced QRS duration (∆QRSd) >35 ms was a significant predictor of ERR+MRR (sensitivity, 68%; specificity, 64%; AUC, 0.7; P=0.003), and paced QTc >443 ms was a negative predictor of ERR+MRR (sensitivity, 78%; specificity, 60%; AUC, 0.7; P=0.002). On Cox proportional hazard modeling, ERR+MRR may reduce risk of ventricular arrhythma around 70% compared with non-responder (HR, 0.29; 95% CI: 0.13-0.65).
Conclusions:
Acute ECG changes after CRT were useful predictors of ERR+MRR. ERR+MRR was also a protective factor for ventricular arrhythmia.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrophysiology of Normal Cardiac Rhythm
