Related Experiment Video
Updated: Oct 12, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Transient Severe Motion Artifact Related to Gadoxetate Disodium-Enhanced Liver MRI: Frequency and Risk Evaluation at
Abstract:
Purpose Varying frequencies (5 - 18 %) of contrast-related transient severe motion (TSM) imaging artifacts during gadoxetate disodium-enhanced arterial phase liver MRI have been reported. Since previous reports originated from the United States and Japan, we aimed to determine the frequency of TSM at a German institution and to correlate it with potential risk factors and previously published results. Materials and Methods Two age- and sex-matched groups were retrospectively selected (gadoxetate disodium n = 89; gadobenate dimeglumine n = 89) from dynamic contrast-enhanced MRI examinations in a single center. Respiratory motion-related artifacts in non-enhanced and dynamic phases were assessed independently by two readers blinded to contrast agents on a 4-point scale. Scores of ≥ 3 were considered as severe motion artifacts. Severe motion artifacts in arterial phases were considered as TSM if scores in all other phases were < 3. Potential risk factors for TSM were evaluated via logistic regression analysis. Results For gadoxetate disodium, the mean score for respiratory motion artifacts was significantly higher in the arterial phase (2.2 ± 0.9) compared to all other phases (1.6 ± 0.7) (p < 0.05). The frequency of TSM was significantly higher with gadoxetate disodium (n = 19; 21.1 %) than with gadobenate dimeglumine (n = 1; 1.1 %) (p < 0.001). The frequency of TSM at our institution is similar to some, but not all previously published findings. Logistic regression analysis did not show any significant correlation between TSM and risk factors (all p > 0.05). Conclusion We revealed a high frequency of TSM after injection of gadoxetate disodium at a German institution, substantiating the importance of a diagnosis-limiting phenomenon that so far has only been reported from the United States and Japan. In accordance with previous studies, we did not identify associated risk factors for TSM. Key Points: · Gadoxetate disodium causes TSM in a relevant number of patients.. · The frequency of TSM is similar between the USA, Japan and Germany.. · To date, no validated risk factors for TSM could be identified.. Citation Format · Well L, Rausch VH, Adam G et al. Transient Severe Motion Artifact Related to Gadoxetate Disodium-Enhanced Liver MRI: Frequency and Risk Evaluation at a German Institution. Fortschr Röntgenstr 2017; 189: 651 - 660.
Insights
Gadoxetate disodium causes significant transient severe motion (TSM) artifacts in liver MRI, with a frequency similar to findings in the USA and Japan. No specific risk factors for TSM were identified in this German study.
Area of Science:
- Radiology
- Medical Imaging
- MRI Artifacts
Background:
- Transient severe motion (TSM) artifacts in gadoxetate disodium-enhanced liver MRI vary between 5-18%.
- Previous TSM reports originated from the United States and Japan.
- This study evaluates TSM frequency in a German institution and potential risk factors.
Purpose of the Study:
- To determine the frequency of TSM artifacts in liver MRI at a German institution.
- To compare TSM frequency between gadoxetate disodium and gadobenate dimeglumine.
- To identify potential risk factors associated with TSM.
Main Methods:
- Retrospective analysis of 178 patients (89 gadoxetate disodium, 89 gadobenate dimeglumine).
- Independent assessment of respiratory motion artifacts by two blinded readers on a 4-point scale.
- Logistic regression analysis to evaluate potential risk factors for TSM.
Main Results:
- The frequency of TSM was significantly higher with gadoxetate disodium (21.1%) compared to gadobenate dimeglumine (1.1%) (p<0.001).
- Mean respiratory motion artifact scores were significantly higher in the arterial phase for gadoxetate disodium.
- No significant correlation was found between TSM and evaluated risk factors (p>0.05).
Conclusions:
- Gadoxetate disodium is associated with a high frequency of TSM artifacts in liver MRI at a German institution.
- The observed TSM frequency is comparable to previously reported data from the USA and Japan.
- No validated risk factors for TSM were identified in this study.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging