Related Experiment Video
Updated: Mar 3, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
[Cemented polyethylene insert in a well fixed Total knee replacement. Case report]
F E García-Dobarganes Barlow1,2,3, J Negrete-Corona4, A A Díaz-Tovar4
1División de Cirugía del Hospital Ángeles Querétaro. Calle Bernardino del Razo 21, Ensueño, 76178 Santiago de Querétaro, Qro. México.
Abstract:
We present the case of a 94 years- old patient, which was operated 14 years ago of a right total knee replacement for osteoarthritis, actually she suffers of pain and instability; her X ray shown polyethylene wear without loosening of the metal components. The polyethylene insert is not manufactured anymore so we decided cement a new polyethylene insert on the native tibial baseplate. The two years follow up show us a patient asymptomatic, good function and no radiolucencies on the tibial component. We only found a similar case report in Madrid and we believed that this decision, taken from total hip revisions, will succeed.