Macro-Raman spectroscopy for bulk composition and homogeneity analysis of multi-component pharmaceutical powders
Hui Wang1, David Barona1, Sulayman Oladepo2
1Department of Mechanical Engineering, University of Alberta, Edmonton, AB T6G 2G8, Canada.
Abstract:
A new macro-Raman system equipped with a motorized translational sample stage and low-frequency shift capabilities was developed for bulk composition and homogeneity analysis of multi-component pharmaceutical powders. Different sampling methods including single spot and scanning measurement were compared. It was found that increasing sample volumes significantly improved the precision of quantitative composition analysis, especially for poorly mixed powders. The multi-pass cavity of the macro-Raman system increased effective sample volumes by 20 times from the sample volume defined by the collection optics, i.e., from 0.02μL to about 0.4μL. A stochastic model simulating the random sampling process of polydisperse microparticles was used to predict the sampling errors for a specific sample volume. Comparison of fluticasone propionate mass fractions of the commercial products Flixotide® 250 and Seretide® 500 simulated for different sampling volumes with experimentally measured compositions verified that the effective sample volume of a single point macro-Raman measurement in the multi-pass cavity of this instrument was between 0.3μL and 0.5μL. The macro-Raman system was also successfully used for blend uniformity analysis. It was concluded that demixing occurred in the binary mixture of l-leucine and d-mannitol from the observation that the sampling errors indicated by the standard deviations of measured leucine mass fractions increased during mixing, and the standard deviation values were all larger than the theoretical lower limit determined by the simulation. Since sample volume was shown to have a significant impact on measured homogeneity characteristics, it was concluded that powder homogeneity analysis results, i.e., the mean of individual test results and absolute and relative standard deviations, must be presented together with the effective sample volumes of the applied testing techniques for any measurement of powder homogeneity to be fully meaningful.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)