Related Experiment Video
Updated: Mar 3, 2026

Amplification of Near Full-length HIV-1 Proviruses for Next-Generation Sequencing
Published on: October 16, 2018
A performance evaluation of Nextera XT and KAPA HyperPlus for rapid Illumina library preparation of long-range
Joseph D Ring1, Kimberly Sturk-Andreaggi1, Michelle A Peck1
1Armed Forces DNA Identification Laboratory, A Division of the Armed Forces Medical Examiner System, 115 Purple Heart Drive, Dover AFB, DE 19902, United States; ARP Sciences, LLC, Contractor Supporting the Armed Forces Medical Examiner System, 9210 Corporate Boulevard, Suite 120, Rockville, MD 20850, United States.
Abstract:
Next-generation sequencing (NGS) facilitates the rapid and high-throughput generation of human mitochondrial genome (mitogenome) data to build population and reference databases for forensic comparisons. To this end, long-range amplification provides an effective method of target enrichment that is amenable to library preparation assays employing DNA fragmentation. This study compared the Nextera XT DNA Library Preparation Kit (Illumina, San Diego, CA) and the KAPA HyperPlus Library Preparation Kit (Kapa Biosystems, Wilmington, MA) for enzymatic fragmentation and indexing of ∼8500bp mitogenome amplicons for Illumina sequencing. The Nextera XT libraries produced low-coverage regions that were consistent across all samples, while the HyperPlus libraries resulted in uniformly high coverage across the mitogenome, even with reduced-volume reaction conditions. The balanced coverage observed from KAPA HyperPlus libraries enables not only low-level variant calling across the mitogenome but also increased sample multiplexing for greater processing efficiency.