Minimal Detectable Change for Balance Measurements in Patients With COPD
Wajdi Mkacher1, Zouhair Tabka, Yassine Trabelsi
1Department of Research: Exercise Physiology and Pathophysiology, Biology, Medicine and Health, UR12ES06, Faculty of Medicine, Sousse University, Sousse, Tunisia.
Purpose:
The purpose of this study was to determine the reliability and minimal detectable change (MDC) of various outcome measures that are potentially suitable for evaluating postural control in individuals with chronic obstructive pulmonary disease (COPD).
Methods:
This was a test-retest reliability study. Participants with COPD were asked to complete 5 balance assessments, separated by 1 week. The assessments included Timed Up and Go (TUG) Test, Unipodal Stance Test (UST), Tinetti Test, Berg Balance Scale (BBS), and the Activities Balance Confidence (ABC) scale. Test-retest reliability using intraclass correlation coefficients and MDC values were calculated for each assessment.
Results:
All 5 outcome measures were found to have excellent test-retest reliability (r > 0.90). The MDC95 values were 3.01 seconds and 4.03 seconds for the TUG Test and the UST, respectively; 3.23 points and 3.46 points for the Tinetti Test and the BBS, respectively; and 8.25% for the ABC scale.
Conclusion:
The TUG, UST, BBS, the Tinetti Test, and the ABC scale are reliable outcome measures for use with people with COPD, recognizing that individual variability of performance is high. Minimal detectable change scores at the 95% CI can be used to assess change in performance over time and the impact of interventions in this population.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Measurement of Blood Pressure
Chronic Obstructive Pulmonary Disease-I: Introduction
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.