Related Experiment Video
Updated: Mar 3, 2026

Development of Sulfidogenic Sludge from Marine Sediments and Trichloroethylene Reduction in an Upflow Anaerobic Sludge Blanket Reactor
Published on: October 15, 2015
Sulfide emissions in sewer networks: focus on liquid to gas mass transfer coefficient
Lucie Carrera1, Fanny Springer1, Gislain Lipeme-Kouyi1
1Univ. Lyon, INSA-Lyon, Laboratory of Waste, Water, Environment, Pollution, 9 rue de la physique, F-69621 Villeurbanne Cedex, France
Abstract:
H2S emission dynamics in sewers are conditioned by the mass transfer coefficient at the interface. This work aims at measuring the variation of the mass transfer coefficient with the hydraulic characteristics, with the objective of estimating H2S emission in gravity pipes, and collecting data to establish models independent of the system geometry. The ratio between the H2S and O2 mass transfer coefficient was assessed in an 8 L mixed reactor under different experimental conditions. Then, oxygen mass transfer measurements were performed in a 10 m long gravity pipe. The following ranges of experimental conditions were investigated: velocity flow [0-0.61 m.s-1], Reynolds number [0-23,333]. The hydrodynamic parameters at the liquid/gas interface were calculated by computational fluid dynamics (CFD). In the laboratory-scale reactor, the O2 mass transfer coefficient was found to depend on the stirring rate (rph) as follows: KL,O = 0.016 + 0.025 N3.85. A KL,H/KL,O ratio of 0.64 ± 0.24 was found, in accordance with previously published data. CFD results helped in refining this correlation: the mass transfer coefficient depends on the local interface velocity ui (m.h-1): KL,O = 0.016 + 1.02 × 10-5 ui3.85 In the gravity pipe device, KL,O also exponentially increased with the mean flow velocity. These trends were found to be consistent with the increasing level of turbulence.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
08:18Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
Published on: June 12, 2016
Related Concept Videos
Gas Solubility
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...
Sulfur Assimilation
The Sulfur Cycle
Preparation and Reactions of Sulfides
Precipitation and Co-precipitation