Temporal and spatiotemporal variability in comprehensive forearm skin microcirculation assessment during occlusion protocols
Related Experiment Video
Updated: Mar 3, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Tomas Strömberg1, Folke Sjöberg2, Sara Bergstrand3
1Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
Abstract:
Forearm skin hyperemia during release after brachial occlusion has been proposed for evaluating peripheral arterial disease and endothelial dysfunction. We used a novel fiberoptic system integrating Laser Doppler Flowmetry and Diffuse Reflectance Spectroscopy for a comprehensive pointwise model based microcirculation characterization. The aim was to evaluate and compare the temporal and the spatiotemporal variabilities in forearm skin microcirculation parameters (speed resolved perfusion; low speed <1mm/s, PerfSR, <1; mid-speed 1-10mm/s, high speed >10mm/s, and total perfusion (PerfSR, tot); the concentration and oxygenation of red blood cells, CRBC and SO2). Ten healthy subjects underwent arterial and venous forearm occlusions (AO, VO), repeated within one week. The repeatability was calculated as the coefficient of variation (CV) and the agreement as the intra-class correlation coefficient (ICC). The temporal CVs for conventional perfusion, Perfconv, PerfSR, tot, CRBC and SO2 were 14%, 12%, 9% and 9%, respectively, while the ICC were >0.75 (excellent). The perfusion measures generally had a higher spatiotemporal than temporal variability, which was not the case for SO2 and CRBC. The corresponding spatiotemporal CVs were 33%, 32%, 18% and 15%, respectively. During VO, CRBC had a CV<35% and ICC>0.40 (fair-good), and after release this was the case for CRBC (AO and VO), SO2 (VO) and PerfSR, <1 (VO). In conclusion, the skin microcirculation parameters showed excellent temporal repeatability, while the spatiotemporal repeatability especially for perfusion was poorer. The parameters with acceptable repeatability and fair-good agreement were: CRBC during and after release of VO, the PerfSR, <1 after release of VO, the SO2 and the CRBC after release of AO. However, the value of these parameters in discriminating endothelial function remains to be studied.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of blood pressure in brachial artery(two-step method)
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....