New method of extracting information of arterial oxygen saturation based on ∑|��|
Wenting Dai1, Ling Lin1, Gang Li1
1State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China.
Abstract:
Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...