Detection of early DJ-stent encrustation by sonographic twinkling-artifacts - a pilot study
Roman A Blaheta1,2, Anton Oertl3,2, Hans-Joachim Freisleben4
1Department of Urology, Goethe University, Frankfurt am Main, Germany.
Introduction:
Ureter obstruction caused by a retro-peritoneal tumor is treated by inserting an indwelling ureter splint (DJ-stent). Indwelling duration is limited by cumulative crystalline deposits into the splint, eventually causing the repeated impairment of urine flow. Deciding when a DJ-stent must be replaced is important since belated removal can be accompanied by severe complications. X-ray or conventional sonography do not allow satisfactory evaluation of early incrustation, therefore, the use of sonographic twinkling artifacts (TA) to provide accurate stent surveillance was investigated.
Material And Methods:
26 patients with indwelling ureter splints carrying a high risk of developing tumor lysis syndrome (TLS), which is often accompanied by early splint incrustation, were investigated utilizing TA the day after DJ-stent implantation and weekly thereafter. Serum creatinine, uric acid, and urine pH were measured at all TA exams.
Results:
Early incrustation of the ureter splint was detected by TA in all patients 1-4 weeks after implantation. Incrustation occurred sooner with increased uric acid levels, and high creatinine or acidic urine accelerated early implant incrustation.
Conclusions:
TA can be used to monitor early crystalline deposits in implanted ureter splints, before they can be detected by conventional sonography or X-ray imaging and before complications occur.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Mitral Stenosis II: Clinical features and Diagnostic Tests