Comparison of physiological measures obtained using the Lode Excalibur Sport cycle ergometer and Tacx i-Magic home
1Directorate of People and Organizational Development, De Montfort University, Leicester, UK - kevin.merry@dmu.ac.uk.
Background:
The aim of this study was to compare several physiological measures obtained using a criterion cycle ergometer (Lode Excalibur Sport) and a commercially-available home training device (Tacx i-Magic).
Methods:
In a randomized, counterbalanced order, eight male amateur club level cyclists (age 30.4±3.5 years, body mass 75.8±8.1 kg, stature 1.75±0.06 m) completed a submaximal and maximal incremental test on both the Lode Excalibur Sport and the Tacx i-Magic.
Results:
Data from the submaximal incremental test revealed that HR was significantly greater during the Lode trials at power outputs of 250 W (P=0.003), 280 W (P<0.001), and 310 W (P<0.001). V̇O2 was significantly greater during the Lode trials at 310 W (P=0.001) and blood lactate was significantly greater during the Lode trials at 310 W (P=0.004). RER was significantly greater during the Lode trials at 310 W (P<0.001). The power output corresponding to the lactate threshold (POLT) was not significantly different between the ergometers (P>0.05). The power output corresponding to a blood lactate concentration of 4 mmol/L (PO4), was significantly greater (P=0.003) during the Tacx trials. V̇O2max was not different between the ergometers (P>0.05), however, the power output associated with V̇O2max (POV̇O2max) (P=0.02), and peak power output (PPO) (P=0.006), were significantly different.
Conclusions:
Cyclists should exercise caution when transferring laboratory based physiological measures to the Tacx i-Magic during exercise >250 W.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
08:26Comparative Analysis of Lower Limb Kinematics between the Initial and Terminal Phase of 5km Treadmill Running
Published on: July 17, 2020
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...