Related Experiment Video
Updated: Mar 3, 2026

Foreign Accent and Forensic Speaker Identification in Voice Lineups: The Influence of Acoustic Features Based on Prosody
Published on: September 27, 2024
Intra-speaker and inter-speaker variability in speech sound pressure level across repeated readings
Antonella Castellana1, Alessio Carullo1, Arianna Astolfi2
1Politecnico di Torino, Department of Electronics and Telecommunications, Corso Duca degli Abruzzi, 24, 10129, Torino, Italy.
Abstract:
The intra- and inter-speaker variability of speech sound pressure level (SPL) has been investigated under repeatability conditions in this work. In a semi-anechoic chamber, speech from 17 individuals was recorded with a sound level meter, a headworn microphone, and a vocal monitoring device. The subjects were asked to read twice and in sequence two phonetically balanced passages. The speech variability has been investigated for mean, equivalent, and mode SPL from each reading and device. The intra-speaker variability has been evaluated by means of the average among individual standard deviations in the four readings and it reached the maximum of 2 dB for mode SPL. For the inter-speaker variability, the experimental standard deviation of individual averaged SPL parameters among the four repeated measures has been calculated, obtaining the highest value of 5.3 dB for mode SPL. Changes in SPL variability have been evaluated with different logging intervals for each device. The influence of speech material has been investigated by the Wilcoxon test on paired lists of descriptive statistics for SPL distribution and equivalent SPL in the repeated readings. The data reported in this study may be considered as a preliminary reference for the investigation of changes in speech SPL over subjects.
Related Concept Videos
Sound as Pressure Waves
The pressure fluctuation depends on the difference in displacements between the successive points in the...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive...
Sound Intensity
Uncertainty in Measurement: Accuracy and Precision
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.