Does Provisional Plating of Closed Tibia Fractures Have Higher Complication Rates?
Justin M Haller1, Michael Githens, John Scolaro
1*Department of Orthopaedic Surgery, University of Utah School of Medicine, Salt Lake City, UT; †Department of Orthopedic Surgery, Harborview Medical Center, University of Washington, Seattle, WA; and ‡Department of Orthopedic Surgery, University of California, Irvine, Orange, CA.
Objectives:
To compare infection and nonunion rates after provisional plating (PP) with standard reduction (SR) techniques for closed tibia fractures treated with an intramedullary nail.
Design:
Retrospective comparative study.
Setting:
Level 1 academic trauma center.
Patients/Participants:
Of the 348 closed tibia fractures (Orthopaedic Trauma Association/Arbeitsgemeinschaft für Osteosynthesefragen 42) treated using an intramedullary nail from January 2007 through June 2015, 231 (40 PP and 191 SR) patients met inclusion/exclusion criteria.
Intervention:
The patients received either a provisional plate or an SR before intramedullary nail placement.
Main Outcome Measurement:
Infection and nonunion.
Results:
The PP cohort had a significantly higher proportion of high-energy injury mechanism and a significantly higher proportion of diabetes than the SR cohort. We were unable to demonstrate a difference in rates of infection [PP cohort (1/40, 2.5%) vs. SR cohort (6/191, 3.1%), P = 1.0], nonunion [PP cohort (3/40, 7.5%) vs. SR cohort (9/191, 4.7%), P = 0.44], or malunion [PP cohort (0/40, 0%) vs. SR cohort (8/191, 4.2%), P = 0.36]. Symptomatic implant removal was similar between the 2 groups [PP cohort (4/40, 10%) vs. SR cohort (27/191, 14%), P = 0.61].
Conclusion:
PP can be used for complex, closed tibia fractures without an increased risk of infection, nonunion, and malunion compared with standard closed reduction techniques.
Level Of Evidence:
Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025