Related Experiment Video
Updated: Mar 3, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Calculation of Dose Rates at the Surface of Storage Containers for High-Level Radioactive Waste
Erik Poenitz1, Clemens Walther1
1Institute for Radioecology and Radiation Protection, Leibniz Universität Hannover, 30419 Hannover, Germany.
Abstract:
In several countries, the high-level radioactive waste that will be disposed of in deep geological formations has to be retrievable for a certain time. Since 2010, retrievability is required for the operation phase of a repository also in Germany. Depending on the effort and the feasibility of remote handling, a certain exposure of the involved employees to ionising radiation is caused. The estimation of the exposure requires the knowledge of the inventory of radionuclides and the radiation field around the storage containers. This paper focuses on German concepts for final storage casks for the drift emplacement in rock salt for both spent fuel rods and high-active waste (HAW) coquilles. Calculations of dose rates at the surfaces of the casks are presented. The calculations show that the gamma radiation of fission and activation products can be efficiently shielded by materials like cast iron or low-alloyed steel. Ductile cast iron, however, has a positive influence on the neutron moderation because of the high carbon content. The shielding of the neutron radiation strongly depends on the quantity and position of the polyethylene (PE) rods which are used as neutron moderator. PE has unfavourable features at elevated temperatures that can be reached in a repository for high-level waste. The simulations show that TiH2 is a promising alternative material for the shielding of neutron radiation. The current assumption that a final storage cask for HAW coquilles has the same outer dimensions as the cask for spent fuel rods will lead to unacceptable dose rates at the side wall. An increase of the diameter is necessary to provide sufficient shielding. Graphite insets in the cask interior lead to a considerably lowered dose rate.
Related Concept Videos
Biological Effects of Radiation
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Drug Accumulation During Multiple Dosing: Repetitive IV Injections

