Related Experiment Video
Updated: Mar 2, 2026

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Molecular Diagnosis of Orthopedic-Device-Related Infection Directly from Sonication Fluid by Metagenomic Sequencing
Teresa L Street1, Nicholas D Sanderson2, Bridget L Atkins3,4
1Nuffield Department of Clinical Medicine, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom teresa.street@ndm.ox.ac.uk.
Abstract:
Culture of multiple periprosthetic tissue samples is the current gold standard for microbiological diagnosis of prosthetic joint infections (PJI). Additional diagnostic information may be obtained through culture of sonication fluid from explants. However, current techniques can have relatively low sensitivity, with prior antimicrobial therapy and infection by fastidious organisms influencing results. We assessed if metagenomic sequencing of total DNA extracts obtained direct from sonication fluid can provide an alternative rapid and sensitive tool for diagnosis of PJI. We compared metagenomic sequencing with standard aerobic and anaerobic culture in 97 sonication fluid samples from prosthetic joint and other orthopedic device infections. Reads from Illumina MiSeq sequencing were taxonomically classified using Kraken. Using 50 derivation samples, we determined optimal thresholds for the number and proportion of bacterial reads required to identify an infection and confirmed our findings in 47 independent validation samples. Compared to results from sonication fluid culture, the species-level sensitivity of metagenomic sequencing was 61/69 (88%; 95% confidence interval [CI], 77 to 94%; for derivation samples 35/38 [92%; 95% CI, 79 to 98%]; for validation samples, 26/31 [84%; 95% CI, 66 to 95%]), and genus-level sensitivity was 64/69 (93%; 95% CI, 84 to 98%). Species-level specificity, adjusting for plausible fastidious causes of infection, species found in concurrently obtained tissue samples, and prior antibiotics, was 85/97 (88%; 95% CI, 79 to 93%; for derivation samples, 43/50 [86%; 95% CI, 73 to 94%]; for validation samples, 42/47 [89%; 95% CI, 77 to 96%]). High levels of human DNA contamination were seen despite the use of laboratory methods to remove it. Rigorous laboratory good practice was required to minimize bacterial DNA contamination. We demonstrate that metagenomic sequencing can provide accurate diagnostic information in PJI. Our findings, combined with the increasing availability of portable, random-access sequencing technology, offer the potential to translate metagenomic sequencing into a rapid diagnostic tool in PJI.
Insights
Metagenomic sequencing of sonication fluid offers a rapid and sensitive diagnostic tool for prosthetic joint infections (PJI). This advanced method shows high accuracy, potentially improving patient outcomes and infection management.
Area of Science:
- Microbiology
- Genomics
- Orthopedic Surgery
Background:
- Current prosthetic joint infection (PJI) diagnosis relies on tissue culture, which has limitations.
- Sonication fluid culture offers additional diagnostic value but can have low sensitivity.
- Prior antibiotic use and fastidious organisms can affect culture results.
Purpose of the Study:
- To evaluate metagenomic sequencing of sonication fluid as a rapid and sensitive diagnostic tool for PJI.
- To compare the diagnostic accuracy of metagenomic sequencing with standard culture methods.
Main Methods:
- Total DNA was extracted from sonication fluid samples.
- Metagenomic sequencing was performed using Illumina MiSeq.
- Taxonomic classification was done using Kraken.
- Results were compared to aerobic and anaerobic cultures from 97 samples.
Main Results:
- Metagenomic sequencing demonstrated high species-level sensitivity (88%) and specificity (88%) compared to sonication fluid culture.
- Genus-level sensitivity reached 93%.
- Human DNA contamination was observed, necessitating rigorous laboratory practices.
Conclusions:
- Metagenomic sequencing is an accurate diagnostic method for PJI.
- The technology holds potential for rapid PJI diagnosis, especially with portable sequencing advancements.
More Related Videos
08:58Isolation and Identification of Waterborne Antibiotic-Resistant Bacteria and Molecular Characterization of their Antibiotic Resistance Genes
Published on: March 3, 2023
18:40Combined In vivo Optical and µCT Imaging to Monitor Infection, Inflammation, and Bone Anatomy in an Orthopaedic Implant Infection in Mice
Published on: October 16, 2014
Related Concept Videos
Modern Molecular Taxonomy
Applications of Molecular Taxonomy
MALDI-TOF Mass Spectrometry