Related Experiment Video
Updated: Mar 2, 2026

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Contemporary transcatheter aortic valve replacement with third-generation balloon-expandable versus self-expanding
Toby Rogers1,2, Arie Steinvil1, Kyle Buchanan1
1Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
Objectives:
To evaluate balloon-expandable and self-expanding third-generation transcatheter aortic valve replacement (TAVR) devices according to patient selection criteria and outcomes.
Background:
Two competing third-generation TAVR technologies are currently commercially available in the US. There are no published head-to-head comparisons of the relative performance of these two devices.
Methods:
257 consecutive patients undergoing TAVR with a third-generation balloon-expandable (Edwards Sapien 3) or self-expanding device (Medtronic CoreValve Evolut R) at a single US medical center were included. Choice of TAVR device was at the discretion of the multidisciplinary Heart Team. Baseline clinical characteristics, echocardiographic and CT imaging, procedural and 30-day outcomes were prospectively collected.
Results:
74 patients received a self-expanding valve (SEV) and 183 received a balloon-expandable valve (BEV). Patients selected for SEV were more frequently women, with lower body surface area and smaller calcified iliofemoral arteries. Three SEV patients required implantation of a second valve to successfully treat paravalvular leak. Only one BEV patient had moderate paravalvular regurgitation. There was no difference in the rate of stroke, major vascular complication or bleeding. Permanent pacemaker implantation rate was significantly higher with SEV (12.7% vs 4.7%, P = 0.49) and hospital length of stay was longer (8.3% vs 6.5%, P = 0.043), but 30-day mortality was comparable (1.4% vs 1.6%, P = 1.00).
Conclusions:
Short-term outcomes were equivalent between the two technologies. Clinically significant paravalvular regurgitation was rare. SEV were more frequently selected in women and patients with challenging transfemoral access, but were associated with higher permanent pacemaker implantation rate and longer hospital length of stay.
Related Concept Videos
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management
Adrenergic Antagonists: ɑ and β-Receptor Blockers
Aneurysm III: Interprofessional Care

