Related Experiment Video
Updated: Mar 2, 2026

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Rapid deployment valve system shortens operative times for aortic valve replacement through right anterior
Constanze Bening1, Khaled Hamouda2, Mehmet Oezkur2,3
1Department of Thoracic and Cardiovascular Surgery, University Hospital Wuerzburg, Wuerzburg, Germany. constanze.bening@googlemail.com.
Background:
There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT.
Methods:
Sixty-eight patients (mean age 76 ± 6 years, 32% females) underwent RAT-AVR between 9/2013 and 7/2015. According to the valve type implanted the patients were divided into two groups. In 43 patients (R-group; mean age 74.1 ± 6.6 years) a rapid deployment valve system (Edwards Intuity, Edwards Lifesciences Corp; Irvine, Calif) and in 25 patients (C-group; mean age 74.2 ± 6.6 years) a conventional stented biological aortic valve was implanted.
Results:
Aortic cross-clamp (42.1 ± 12 min vs. 68.3 ± 20.3 min; p < 0.001) and bypass time (80.4 ± 39.3 min vs. 106.6 ± 23.2 min; p = 0.001) were shorter in the rapid deployment group (R-group). We observed no differences in clinical outcome. Postoperative gradients (R-group: max gradient, 14.3 ± 8 mmHg vs. 15.5 ± 5 mmHg (C-group), mean gradient, 9.2 ± 1.7 mmHg (R-group) vs. 9.1 ± 2.3 mmHg (C-group) revealed no differences. However, larger prostheses were implanted in C-group (25 mm; IQR 23-27 mm vs. 23 mm; IQR 21-25; p = 0.009).
Conclusions:
Our data suggest that the rapid deployment aortic valve system reduced cross clamp and bypass time in patients undergoing RAT-AVR with similar hemodynamics as with larger size stented prosthesis. However, larger studies and long-term follow-up are mandatory to confirm our findings.