[Radiographic implications of procedures involving cardiac implantable electronic devices (CIEDs) - Selected aspects]
Roman Steckiewicz1, Dariusz Artur Kosior2, Elżbieta Barbara Świętoń3
1Warszawski Uniwersytet Medyczny / Medical University of Warsaw, Warszawa, Poland (I Katedra i Klinika Kardiologii / 1st Department of Cardiology). r.steckiewicz@pro.onet.pl.
Background:
Some cardiac implantable electronic device (CIED) implantation procedures require the use of X-rays, which is reflected by such parameters as total fluoroscopy time (TFT) and dose-area product (DAP - defined as the absorbed dose multiplied by the area irradiated).
Material And Methods:
This retrospective study evaluated 522 CIED implantation (424 de novo and 98 device upgrade and new lead placement) procedures in 176 women and 346 men (mean age 75±11 years) over the period 2012-2015. The recorded procedure-related parameters TFT and DAP were evaluated in the subgroups specified below. The group of 424 de novo procedures included 203 pacemaker (PM) and 171 implantable cardioverter-defibrillator (ICD) implantation procedures, separately stratified by single-chamber and dual-chamber systems. Another subgroup of de novo procedures involved 50 cardiac resynchronization therapy (CRT) devices. The evaluated parameters in the group of 98 upgrade procedures were compared between 2 subgroups: CRT only and combined PM and ICD implantation procedures.
Results:
We observed differences in TFT and DAP values between procedure types, with PM-related procedures showing the lowest, ICD - intermediate (with values for single-chamber considerably lower than those for dual-chamber systems) and CRT implantation procedures - highest X-ray exposure. Upgrades to CRT were associated with 4 times higher TFT and DAP values in comparison to those during other upgrade procedures. Cardiac resynchronization therapy de novo implantation procedures and upgrades to CRT showed similar mean values of these evaluated parameters.
Conclusions:
Total fluoroscopy time and DAP values correlated progressively with CIED implantation procedure complexity, with CRT-related procedures showing the highest values of both parameters. Med Pr 2017;68(3):363-374.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiac Catheterization III: Left Heart Catheterization