Poster - Thurs Eve-18: Performance evaluation of MV CT imaging on the HI ART II tomotherapy unit
B Disher1,2, S Gaede2, J J Battista1,2
1Department of Medical Biophysics, University of Western Ontario, London, ON.
Abstract:
The HI-ART II unit (TomoTherapy Inc., Madison WI) is a modality used by the London Regional Cancer Program (LRCP) for radiation therapy. This machine uses the same source of Megavoltage energy radiation to image (3.5 MV) and to treat (6MV) patients, combining the functionality of a traditional linear accelerator and CT simulator into one unit. Thus, it is possible to assess patient positioning and adjust for anatomy changes just prior to radiation therapy. Unfortunately, at MV energy levels, the physics of radiation interaction limits image quality, and gives rise to an inherent dose limitation concern that enhances noise levels. Therefore, we propose to quantify the image quality produced by the HI-ART II unit using techniques established for kVCT scanner technology. Our study involved the use of three standard phantoms to test image resolution, noise, uniformity, and linearity for a 512 × 512 reconstruction matrix and three scan pitch settings (0.8, 1.6, and 2.4). Results follow: linearity between MV CT number versus relative electron density was observed, noise calculations ranged from 2.15-2.51%, and a distinct central artifact was revealed during uniformity testing. The linearity between MV CT number versus relative electron density implies that MV CT images are highly suitable for dose calculations. MV CT image quality of uniform phantoms were acceptable and demonstrated noise levels higher than those produced by kVCT simulators. Further study is necessary to correct for the central artifact in MV CT images.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:25Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...