Related Experiment Video
Updated: Mar 2, 2026

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
Published on: May 27, 2008
Poster - Thurs Eve-16: Just-in-time tomography (JiTT).
1Odette Cancer Centre, Departments of Radiation Oncology and Medical Biophysics, University of Toronto, Toronto, ON.
Just-in-time tomography (JiTT) offers a faster imaging solution for radiation therapy, overcoming limitations of cone beam computed tomography (CBCT) for tracking soft-tissue target motion during treatment.
Area of Science:
- Medical Physics
- Radiotherapy Technology
- Medical Imaging
Background:
- Soft-tissue target motion presents a significant challenge in high-precision radiation therapy.
- Current image-guided radiation therapy relies on cone beam computed tomography (CBCT), which has limitations in imaging intrafraction motion due to long acquisition times.
Purpose of the Study:
- To introduce and investigate the feasibility of a novel imaging concept, just-in-time tomography (JiTT), for image-guided radiation therapy.
- To address the inadequacy of existing methods for capturing real-time target motion during radiation delivery.
Main Methods:
- Proposed a new system designed to achieve just-in-time tomography (JiTT).
- Investigated the feasibility of the proposed JiTT system for generating rapid tomographical and beam's-eye-view images.
- Focused on imaging soft-tissue targets with intrafraction motion.
Main Results:
- JiTT significantly reduces image acquisition time compared to conventional CBCT.
- The proposed system is capable of generating necessary tomographical and beam's-eye-view images quickly.
- Demonstrated the potential for JiTT to provide real-time imaging for radiation therapy guidance.
Conclusions:
- Just-in-time tomography (JiTT) is a promising advancement for image-guided radiation therapy.
- JiTT overcomes the limitations of CBCT in addressing intrafraction motion.
- The developed system shows feasibility for real-time imaging in radiation therapy, enhancing treatment precision.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...