Related Experiment Video
Updated: Mar 2, 2026

Quantification of Optic Nerve Cross Sectional Area on MRI: A Novel Protocol using Fiji Software
Published on: September 4, 2021
Assessment of nonarteritic anterior ischemic optic neuropathy with intravoxel incoherent motion diffusion-weighted
Ping Lu1,2, Yan Sha2, Hailin Wan2
1Shanghai Institution of Medical Imaging, Zhongshan Hospital, Fudan University, Shanghai, P.R. China.
Purpose:
To determine the feasibility of intravoxel incoherent motion (IVIM) for characterizing perfusion properties and its potential diagnostic utility for nonarteritic anterior ischemic optic neuropathy (NAION). IVIM diffusion-weighted imaging is a promising technique that can measure perfusion and diffusion characteristics simultaneously in a noninvasive manner.
Materials And Methods:
Orbital IVIM in a 3.0T scanner was performed on 33 patients with NAION and 15 controls using readout-segmented echo-planar imaging, parallel imaging, and 2D navigator-based reacquisition (RESOLVE-IVIM). Both visual field (VF) and visual acuity (VA) examinations were performed in 19 of the patients. The vascular volume fraction (f), diffusion coefficient (D), and pseudodiffusion coefficient (D*) were calculated for quantitative analysis. Additionally, correlation analyses of IVIM parameters with visual function were also performed.
Results:
Affected optic nerves showed significantly lower f values than both unaffected contralateral nerves of the patients and nerves of the controls (P < 0.0001), and no significant difference for f was found between unaffected contralateral nerves and nerves of the controls (P = 0.1602). In addition, D and D* values showed no significant differences among the three groups (P = 0.0979, 0.0600, 0.6136 for D and 0.1779, 0.6253, 0.4743 for D*). Correlation analysis only demonstrated significant correlations between f values and the mean deviation of the visual field (r = 0.576, P = 0.0051).
Conclusion:
RESOLVE-IVIM measurement may reflect the perfusion abnormality and visual function impairment in NAION patients, demonstrating its potential application for the diagnosis and clinical evaluation of NAION.
Level Of Evidence:
1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017;46:1760-1766.
More Related Videos
17:16Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
06:45Author Spotlight: Integrated Photoacoustic, Ultrasound, and Angiographic Tomography (PAUSAT) for NonInvasive Whole-Brain Imaging of Ischemic Stroke
Published on: June 2, 2023
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System IV: CMRI