Related Experiment Video
Updated: Mar 2, 2026

Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping
Published on: September 25, 2019
Evaluation of hyperacute infarct volume using ASPECTS and brain CT perfusion core volume
Jelle Demeestere1, Carlos Garcia-Esperon1, Pablo Garcia-Bermejo1
1From the Acute Stroke Service (J.D., C.G.-E., F.O., M.P., C.L.), John Hunter Hospital, Newcastle, Australia; Hamad Medical Corporation (P.G.-B.), Doha, Qatar; Hunter Medical Research Institute (P.M., A.B.), Newcastle; and University of Newcastle (P.M., M.P., C.L.), Callaghan, Australia.
Objective:
To compare the accuracy of Alberta Stroke Program Early Computed Tomography Score (ASPECTS) and CT perfusion to detect established infarction in acute anterior circulation stroke.
Methods:
We performed an observational study in 59 acute anterior circulation ischemic stroke patients who underwent brain noncontrast CT, CT perfusion, and MRI within 100 minutes from CT imaging. ASPECTS scores were calculated by 4 blinded vascular neurologists. The accuracy of ASPECTS and CT perfusion core volume to detect an acute MRI diffusion lesion of ≥70 mL was evaluated using receiver operating characteristics analysis and optimum cutoff values were calculated using Youden J.
Results:
Median ASPECTS score was 8 (interquartile range [IQR] 5-9). Median CT perfusion core volume was 22 mL (IQR 10.4-71.9). Median MRI diffusion lesion volume was 24.5 mL (IQR 10-63.9). No significant difference was found between the accuracy of CT perfusion and ASPECTS (c statistic 0.95 vs 0.87, p value for difference = 0.17). The optimum ASPECTS cutoff score to detect a diffusion-weighted imaging lesion ≥70 mL was <7 (sensitivity 0.74, specificity 0.86, Youden J = 0.60) and the optimum CT perfusion core volume cutoff was ≥50 mL (sensitivity 0.86, specificity 0.97, Youden J = 0.84). The CT perfusion core lesion covered a median of 100% (IQR 86%-100%) of the acute MRI lesion volume (Pearson R = 0.88; R2 = 0.77).
Conclusions:
We found no significant difference between the accuracy of CT perfusion and ASPECTS to predict hyperacute MRI lesion volume in ischemic stroke.
More Related Videos
09:48Quantification of Neurovascular Protection Following Repetitive Hypoxic Preconditioning and Transient Middle Cerebral Artery Occlusion in Mice
Published on: May 4, 2015
08:12A Volumetric Method for Quantification of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage
Published on: July 28, 2018
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...