Related Experiment Video
Updated: Jul 24, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Sci-Thur AM: Planning - 12: Comparative study of SBRT lung dose calculation using Eclipse and Monte Carlo
Abstract:
Stereotactic Body Radiation Therapy (SBRT) is an option for early stage non-small cell lung cancer treatment. In SBRT treatment, high biological effective dose is delivered to the patient within a small number of fractions. High level of confidence in accuracy is required in the entire treatment procedure, from patient setup, tumour delineation, treatment simulation and planning, to the final dose delivery. SBRT lung treatment utilizes small fields that are incident on large tissue inhomogeneities within the patient. It is difficult for commercially available treatment planning systems (TPS) to model the lack of charged particle equilibrium and the dose near tissue-lung interfaces accurately. The Monte Carlo (MC) technique calculates the dose distribution from the first principles thereby providing a feasible tool for verifying the dose distribution computed from TPS. In this study, we compared the SBRT dose distribution between Eclipse 8.9 and BEAMnrc/DOSXYZnrc for both conformal and RapidArc plans. Calculation results for five clinical SBRT conformal lung plans were compared. Eclipse and MC results for each plan showed good agreement in dose received by organs at risk. MC simulation predicted uniformly hotter or similar PTV coverage for three cases with tumor either small or attached to the chest wall. When tumor is inside lung and at relatively medium to larger size for SBRT, MC predicted lower PTV coverage. The variation in dose coverage may depend on the tumour size and its position within the lung. Dose comparison for RapidArc plans shows similar dependence.
More Related Videos
Related Concept Videos
Radiation: Applications
The average...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

