Related Experiment Video
Updated: Jul 30, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Poster - Thur Eve - 31: RapidArc total body photon irradiation: A feasibility study
Mdc Evans1, R Ruo1, J Seuntjens1
1Medical Physics, McGill University Health Centre and McGill University, Montreal, QC, Canada.
Abstract:
Total body photon irradiation (TBI) may be delivered with a number of standard techniques, typically using extended SSD geometries to obtain large field sizes. Since 1982 we have treated over 620 patients (adult and pediatric) mostly in the floor-located prone/supine treatment position with AP/PA beams using a column mounted 4 MV linac, and more recently with a fixed field, extended SSD, Cobalt teletherapy unit. This treatment position has many advantages for TBI including ease of delivery (especially for pediatric or compromised patients), improved dose uniformity, simplicity for partial or complete organ shielding, and imaging capabilities to name a few. In an effort to transfer this technique to a conventional isocentric linac, we have undertaken a feasibility study for RapidArc based extended SSD total body irradiation. Proof of principle was first explored using the DBD (Dynamic Beam Delivery) toolbox to configure a 6 MV beam with an 80 degree arc, centered on the 12 o'clock gantry angle with a sliding-window beam. This was followed by the development of an ECLIPSE generated 80 degree RapidArc plan. Initial measurements were conducted with a Varian 21EX using the 6 MV DBD beam to explore characteristics such as PDD, surface dose, off-axis ratios, output, dose per MU, and linearity. Subsequently ECLIPSE generated RapidArc TBI plans using similar partial arcs were also evaluated. Encouraged by our results, we believe this technique shows potential for making floor-located AP/PA total body photon irradiation possible for any standard RapidArc enabled isocentric linac.
More Related Videos
08:31Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
Published on: June 27, 2022
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...