Poster - Thur Eve - 44: Digital tomosynthesis image quality in a Co-60 treatment beam
M Marsh1, L J Schreiner1,2, A Kerr1,2
1Department of Physics, Queen's University, Kingston, ON, Canada.
Abstract:
Image guidance capability is an important feature of modern radiotherapy machines. Cobalt-60 units will require some form of image guidance if they are to be brought up to modern standards. Imaging in the treatment beam is an appealing option, for reasons of simplicity and cost, but the dose needed to produce cone beam CT images in a Co-60 treatment beam is too high for this modality to be clinically useful. Digital tomosynthesis (DT) offers a quasi-3D image, of sufficient quality to identify bony anatomy or fiducial markers, while delivering a much lower dose than CBCT. A series of experiments were conducted on a prototype Co-60 cone beam imaging system to quantify the resolution, selectivity, geometric accuracy and contrast sensitivity of Co-60 DT. Although the resolution was severely limited by the penumbra cast by the ∼2cm diameter source, it was possible to identify high contrast objects on the order of 1 mm in width, and bony anatomy in anthropomorphic phantoms was clearly recognizable. Low contrast sensitivity down to electron density differences of 3% was obtained, for uniform features of similar thickness. The conventional shift-and-add algorithm was compared to the FDK filtered backprojection algorithm using several different spatial filters. The Co-60 DT images were obtained with a total dose of 5 to 15 cGy. We conclude that, should Co-60 radiotherapy units be upgraded with image guidance capabilities, filtered backprojection DT in the treatment beam is a versatile and promising modality that would be well suited to the task of patient positioning.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
X-ray Imaging