Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Search for Light Pseudoscalar Bosons, Pair-Produced in Higgs Boson Decays in the Four-Electron Final State in Proton-Proton Collisions at sqrt[s]=13  TeV.

Physical review letters·2026
Same author

First Evidence for Mixing-Induced CP Violation in B_{s}^{0}→J/ψϕ(1020) Decays in pp Collisions at sqrt[s]=13  TeV.

Physical review letters·2026
Same author

INVITED REVIEW: A review of dairy quality assurance programs: What do we know and where are we headed?

Journal of dairy science·2026
Same author

Observation of Suppressed Charged-Particle Production in Ultrarelativistic Oxygen-Oxygen Collisions.

Physical review letters·2026
Same author

Measurement of D^{0} Meson Photoproduction in Ultraperipheral Heavy Ion Collisions.

Physical review letters·2026
Same author

Intrinsic Berry Curvature Driven Anomalous Hall and Nernst Effect in Co<sub>2</sub>MnSn.

Small (Weinheim an der Bergstrasse, Germany)·2026

Related Experiment Video

Updated: Mar 2, 2026

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
06:33

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement

Published on: July 29, 2013

11.7K

SU-E-T-97: Intra and Inter Variability in Beam Data Commissioning among Water Phantom Scanning Systems.

I Das1,2,3, C Chu1,2,3, J Conlon1,2,3

  • 1Indiana University-School of Medicine, Indianapolis, IN.

Medical Physics
|May 19, 2017
PubMed
Summary

Modern water-phantom scanning systems show minimal intra- and inter-variability in commissioning data, typically within ±0.2% accuracy. This indicates high reliability for beam data collection across different vendors and equipment.

Keywords:
Computer softwareData analysisElectron beamsImage detection systemsParticle beam detectorsPhotons

More Related Videos

Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol
07:59

Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol

Published on: September 7, 2018

12.2K
Irradiator Commissioning and Dosimetry for Assessment of LQ &#945; and &#946; Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.8K

Related Experiment Videos

Last Updated: Mar 2, 2026

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
06:33

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement

Published on: July 29, 2013

11.7K
Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol
07:59

Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol

Published on: September 7, 2018

12.2K
Irradiator Commissioning and Dosimetry for Assessment of LQ &#945; and &#946; Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.8K

Area of Science:

  • Medical Physics
  • Radiation Oncology
  • Radiotherapy Physics

Background:

  • Accurate commissioning data is crucial for radiotherapy treatment planning.
  • Various water-phantom scanning systems exist, but their data variability is not well-documented.

Purpose of the Study:

  • To assess the intra- and inter-variability of commissioning data collected by modern water-phantom scanning systems.
  • To evaluate the reliability and consistency of data from different vendors.

Main Methods:

  • Four vendors' water-phantom scanning systems (PTW, Sun Nuclear, Standard Imaging, IBA) were used.
  • Percent depth dose (PDD) and profile data were collected for photon and electron beams.
  • Intra-variability was assessed through repeated measurements; inter-variability was assessed using single setups from each vendor.

Main Results:

  • Intra-variability was consistently low (±0.1%) across all vendors.
  • Inter-variability for PDDs was slightly higher but within acceptable ranges (e.g., 0.02±0.17% for SI vs PTW).
  • Profile inter-variability was <0.1% in central regions but up to ±4.8% in penumbra; polarity effects up to 3% were observed.

Conclusions:

  • Modern water-phantom scanning systems demonstrate minimal variability, achieving data accuracy within ±0.2% when used correctly.
  • System selection should prioritize user comfort with software and hardware.