A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
SU-E-T-293: The Potential Application of High Energy Proton Beam-Induced Positron for PET Imaging Technique
E Kumi Barimah1, K Shahnazi1, C Keppel1
1Hampton, VA.
Purpose:
An existing nuclear interaction cross-section of a positron emitter was used to predict range accuracy of proton beams and cross section of the positron emitters detected by the PET scanner Methods: To achieve this goal, a MLIC phantom was irradiated to 2Gy dose using 124.61MeV, 143.08MeV and 155.25MeV proton beam corresponding to the depths of 6.88cm, 10cm and 16cm, respectively, in the phantom. The activity produced in each phantom was examined by PET scanner within a couple of minutes post-irradiation. Hence, activity signal produced along the activated depth dose profile was recorded. In this project, the isotope production cross section for carbon from Landolt-Bornstein (1973) has been utilized.
Results:
A good correlation (about 95%) between the positron emission and the isotope cross section of the carbon was observed. Consistency between the induced activity and the carbon isotope cross section occurred mainly at the distal aspect of the fall off zone of both relative cross-sections (i.e. between 60 - 100%). These results were obtained using the high relative abundance of carbon (i.e. 70%) in the phantoms.Conclusions The ranges measured by the depth dose profiles and positron emission profiles were in good agreement at the distal-fall off edge. Furthermore, it is confirmed that the interaction cross-sections of individual elements in the tissues could be used to determine the range accuracy of the proton depth dose profiles. None Applicable.
More Related Videos
09:08Enhancing Efficiency and Radiolabeling Yields of Carbon-11 Radioligands for Clinical Research Using the Loop Method
Published on: December 20, 2024
10:47Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)