Related Experiment Video
Updated: Mar 2, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
SU-E-T-462: Calculation of Prescribed Dose for Permanent Implant with Cs-131 Using LQ Equation including
Purpose:
To develop a new biological equivalent dose (BED) formulism that includes repair, repopulation and resensitization (redistribution and reoxygenation), and can be used to calculate prescribed dose for permanent implant with Cs-131.
Methods:
Because of lack of sufficient clinical data, the prescribed dose with new isotopes is usually calculated based on BED compared with other isotopes that have already been used in clinical practice. The current widely used formulism of BED calculation for permanent implant which was given by Dale includes cell repair and repopulation but not resensitization. Resensitization can be included in the extended LQ equation (LQR) proposed by Brenner. Applying Dales formulism to Brenners LQR, we obtained a new BED calculation formula that accounts for resensitization. We used this new formulism to calculate the BED that corresponds to the prescribed dose for cervix (with Au-198) and prostate (with I-125) permanent implant. Then, we obtained the prescribed dose with Cs-131 which has the same BED as Au-198 or I-125.
Results:
The new formulism was used for prostate and cervix cancer permanent implant. The prescribed dose with Cs-131 for cervix was 40 Gy (42 Gy without resensitization) and 66 Gy (69 Gy without resensitization) which were equivalent to 35 Gy and 60 Gy with Au-198, respectively. For prostate implant, the prescribed dose with Cs-131 that corresponded to 144 Gy with I-125 was 135 Gy (124 Gy without resensitization).
Conclusion:
Resensitization led to significant dose correction for permanent implant. The calculation of BED and dose was dependent on dose itself and thus should be patient-specific. Since this calculation relied on many biological parameters, and may not be accurate if the parameters are not accurate. Also, the dose prescription should be adjusted based on clinical outcomes.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
IV Infusion to Oral Dosing: Conversion Methods
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dosage Regimens: Designs and Approaches