SU-E-I-89: Applying Image Gently and Image Wisely in Nuclear Medicine
Insights
Nuclear medicine departments should align radiopharmaceutical doses with Image Gently® and Image Wisely™ guidelines. Adjusting doses ensures patient safety and optimizes imaging quality, comparable to CT scan radiation levels.
Area of Science:
- Medical Imaging
- Nuclear Medicine
- Radiation Safety
Background:
- Radiation dose reduction is a critical aspect of medical imaging safety.
- Nuclear medicine procedures account for a significant number of annual imaging studies.
- The Image Gently® and Image Wisely™ campaigns provide guidelines for dose optimization.
Purpose of the Study:
- To demonstrate the clinical implementation of Image Gently® and Image Wisely™ principles.
- To evaluate radiopharmaceutical doses in a nuclear medicine department.
- To ensure adherence to national and international radiation dose recommendations.
Main Methods:
- Implemented Image Gently® and Image Wisely™ guidelines as a quality improvement project.
- Compared pediatric radiopharmaceutical doses to North American and European guidelines.
- Compared adult radiopharmaceutical doses to NCRP and IAEA standards.
Main Results:
- Most administered radiopharmaceutical doses were comparable to recommended values.
- Pediatric renogram and adult gastric emptying doses were adjusted to meet guidelines.
- Resultant image quality was evaluated after dose adjustments.
Conclusions:
- Nuclear medicine radiation doses warrant attention, similar to CT dose reduction efforts.
- Departments should benchmark pediatric and adult doses against established guidelines.
- Adjusting non-comparable doses and employing additional dose-reduction strategies are recommended.
Purpose:
To demonstrate how principles and recommendations of the Image Gently® and Image Wisely™ campaigns can be clinically implemented.
Methods:
Implementation of Image Gently® and Image Wisely™ guidelines was a quality and safety improvement project for our Nuclear Medicine department in 2011. Pediatric administered radiopharmaceutical doses were compared to recommended doses in the North American Consensus Guidelines for AdministeredRadiopharmaceutical Activities in Children and Adolescents and the European Association of Nuclear Medicine Paediatric Dose Card. Adult administered radiopharmaceutical doses were compared to administered doses in NCRP Report No. 160 and IAEA Report No. 40.
Results:
Evaluation of site administered radiopharmaceutical doses showed that nearly all doses were comparable to those recommended by national and international advisory bodies. Administered doses for the pediatric renogram and the adult gastric emptying were adjusted to match the recommendations and resultant image quality evaluated.
Conclusions:
Radiation dose from nuclear medicine procedures should not be overlooked in the focus on CT dose reduction. An estimated 19.7 million nuclear medicine procedures are done annually in the U.S., with doses comparable to that from CT scans. Nuclear medicine departments should evaluate their pediatric administeredradiopharmaceutical doses against the North American Consensus Guidelines for Administered Radiopharmaceutical Activities in Children and Adolescents and evaluate their adult doses against national and international standards. Administered doses that are not comparable to the recommended values should be adjusted accordingly. Additional steps to reduce patient radiation dose include decision support to reduce inappropriate ordering, technique optimization for the CT scan portion of SPECT/CT and PET/CT, use of vendor's dose reduction camera and software technology, use of shorter lived radiopharmaceuticals, and 'right sizing' patient doses by weight.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Ultrasonography
During an ultrasonography procedure, a handheld device called...