SU-E-J-151: Evaluation of a Real Time Tumour Autocontouring Algorithm Using In-Vivo Lung MR Images with Various
Purpose:
To quantitatively evaluate a lung tumour autocontouring algorithm using in-vivo lung cancer patient MR images with varying contrast to noise ratios (CNR) simulating images acquired at various MR field strengths.
Methods:
A non small cell lung cancer patient with posterior lung tumour is imaged (sagittal plane) in a 3T MRI using a dynamic bSSFP sequence (FOV: 40×40cm2 , voxel size: 3.1×3.1×20mm3 , TE = 1.1ms. TR = 2.2ms, 275ms per image) under free breathing for approximately 3 minutes (650 images). Gaussian random noise is added to the 3T images to approximately simulate the equivalent CNR in images acquired at 1.5T, 1.0T, 0.5T, 0.3T and 0.2T. The moving tumour in all 3T images is contoured by a physician for reference. The first 20 of these manual contours are used for the parameters optimization of auto-contouring algorithm. The automatic contours from the remaining images are quantitatively compared with the physician's contours using the centroid's displacement and the Dice's coefficient (DC).
Results:
The oncologist's contours of the 3T images show a maximum S-I motion of 26mm. Compared to the oncologist's contours, automatic contours have an average centroid displacement of 1.37mm, and an average DC of 0.881. The autocontouring algorithm's performance with images in the range of 1.5T to 0.5T equivalent CNRs is similar to that of the 3T data. However, for the lowest CNR datasets (0.2, 0.3T) an increase in centroid displacement and decrease in DC is observed, with mean displacements of 1.56mm, 1.71mm and DCs of 0.870, 0.836 for the 0.3T and 0.2T dataset, respectivelyConclusions: With in-vivo MR images, the autocontouring algorithm generated lung tumour contours similar to ones drawn by a physician (DC 〉 0.83). In this patient, additional CNR from 〉0.5T MRIs does not provide statistically significant improvement in the accuracy of our autocontouring software. E.Yip is supported by the Canadian Institutes of Health Research as well as Alberta Innovates - Health Solutions.
More Related Videos
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography