SU-E-J-182: Patient Specific Assessment of External Radiation Exposure to Bystanders Interacting with Patients
Purpose:
Conventional calculation methods of patient release criteria for compliance with NRC regulations are based on the assumption that both patient and bystander are each a single point in space. This study was intended to assess the patient-specific external radiation exposure to a bystander interacting with the patient following radionuclide therapy with 131I.
Methods:
131I-sodium iodide treatment for hyperthyroidism and thyroid cancer and 131I-tositumomab treatment of non-Hodgkin's lymphoma were considered. 131I distribution provided by the patient SPECT image was rendered on the SPECT-fused CT images. The CT images were then imported to a Monte Carlo based simulation code, MCNPX 2.7, as a source phantom. For a target phantom, we employed the adult male hybrid phantom developed at the University of Florida and National Cancer Institute. A single orientation - patient and a bystander facing one another at 1.0 m - was considered. S factors (dose per unit cumulative activity (A)) for each organ in a bystander was obtained from the MC calculations and effective dose (EDE) per A was calculated based on tissue-weighted individual organ doses. The results were compared with the calculations using UF/NCI adult hybrid source/target phantoms and the revised adult ORNL stylized source/target phantoms.
Results:
EDE per A of the stylized phantom was 1.5% higher than that of the hybrid phantom for uniform source localization in the thyroid. However, EDE per A of the hybrid phantom was 20% less than that of stylized phantoms for a torso source. The difference is attributed to the realistic shape of the frontal body comparing to the simple ellipsoidal trunk of the stylized phantom.
Conclusions:
Based on the realistic hybrid phantoms and accurate MC radiation transport calculation tools, patient specific dosimetry for a bystander is feasible. S factors will be calculated using the patient CT image with 131I bio-distributions and hybrid phantoms.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET