SU-E-I-30: Impact of Physician Practice on Patient Radiation Dose during CT Guided Biopsy Procedures
Purpose:
The major concern with CT fluoroscopy is patient radiation dose, which is determined by applied technical parameters as well as practitioner/operator practice, e.g. habits and choice of dose saving features. This study is to investigate the effects of these intangible factors on patient doses.
Methods:
381 patients underwent CT biopsy were retrospectively studied. Patient doses (dose length product, DLP) were analyzed and compared. Comparisons were made among physicians using only conventional intermittent shots, physicians using a low mA dose saving feature, and physicians using a combination of both. Linear regression analyses were performed to investigate any possible relationship between the variables and the patient dose. The Patient detriment index (PDI) was developed to set a threshold for the purpose of the Joint Commission sentinel dose events monitoring. An odds ratio was calculated to determine the odds of a group of patients receiving a dose above the median threshold when compared to another group.
Results:
The median DLP for all physicians was 1194 mGy-cm. There is a significant difference (p<0.01) between the doses patients received (DLP=539.8 ±76 mGy-cm) when physicians used dose saving feature vs. when the feature was not used (DLP=1269.7±659 mGy-cm). In general, those physicians who used dose saving feature have a lower relative PDI (<1) compared to the PDIs (>1) without dose feature. This is not absolute since some physicians who did not use the dose saving feature have PDIs
Conclusions:
Adjustments of practice habits, the use of CT dose saving features or both may be needed to improve patient care for CT fluoroscopy.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...