Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
SU-E-J-79: Using the Distance of Closest Approach to Improve Compton Camera Image Quality
D Mackin1,2,3, S Peterson1,2,3, J Polf1,2,3
1MD Anderson Cancer Center, Houston, TX.
Purpose:
The prompt gamma radiation emitted from tissue during proton therapy offers a means of beam range verification. Compton camera (CC) imaging systems offer high efficiency and 3D imaging capability. However, Doppler broadening and the inaccuracies in the measurement of the scattering positions and energies reduce the image resolution. The purpose of our study is to determine if removing events with a distance-of-closest-approach greater than a threshold value will improve the resolution of images reconstructed using the stochastic origins ensemble (SOE) algorithm.
Methods:
We first simulated a 3-stage CC detecting gammas from a 0.511 MeV point source. We then used SOE to reconstruct images from the point source and from a) all gammas, b) gammas with DCA < 3 mm, and c) gammas with DCA < 1 mm. We measured the point-spread-function for the point source for a), b), and c). Next, we simulated a 3-stage CC detecting prompt gammas emitted from tissue during proton therapy. We reconstructed the gammas using SOE and compared 2D images of all gammas, gammas with DCA < 3 mm, and gammas with DCA < 1 mm.
Results:
The FWHM of the PSF of the 0.511 MeV point source was reduced by 50% when DCA was required to be < 5 mm, and it was reduced by 65% when DCA was required to be < 3 mm. 2D images of a proton beam are of visibly higher quality as the DCA requirement is lowered.
Conclusions:
The DCA for MC events can be used to identify the events with significant resolution loss due to the detector effects. Removing these events before running the reconstruction algorithm results in higher quality images. We discuss methods to predict the DCA based on the measured scatter data, so that a similar technique can be applied to data from real detectors. This work was supported by the National Institutes of Health through award number R21CA137362 from the National Cancer Institute.
Related Concept Videos
Distance Corrections
Distance Measurements by Taping
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Sight Distance in a Vertical Curve
Light Acquisition
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...