Related Experiment Video
Updated: Mar 2, 2026

In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
Efficacy of camera sleeve in conveyance of conduits
1Armed Forces Medical College, Department of Surgery, Pune, India.
Background:
Esophageal substitutes need conveyance from the abdomen into the neck for restoration of alimentary continuity. Reports suggest that the use of plastic camera sleeve may prove advantageous in restoring conveyance. This study aims to evaluate the practicability of this approach, specifically, in laparoscopy-assisted surgeries.
Methods:
The efficacy of camera sleeve in conduit transposition was prospectively evaluated over 2 years. The following parameters were assessed: success/failure; time taken; blood loss; adequacy of length of the conduit delivered into the neck; conduit orientation; ease of procedure through different routes; conduit damage; complications; and drawbacks.
Results:
The technique was used in 25 consecutive patients. Two ileo-colonic, 13 gastric, and 10 colonic conduits were transposed. Posterior mediastinal, retro-sternal, and ante-sternal routes were used in 15, 8, and 2 cases, respectively. There were no failures. The technique was easy to adopt. It added < 10 minutes to the procedure. It entailed no additional blood loss. Adequate length of the conduit was transposed into the neck, atraumatically. Conduits maintained their orientation without effort. Although no complications per se were associated with its use, extra conduit length became transposed into the neck, twice, necessitating its trimming/adjustment. In one case, traction suture became avulsed from the conduit, midway in the tunnel. This could easily be rectified by pulling out the sleeve from the neck, which brought up the conduit along with it, as desired.
Conclusions:
Use of camera sleeve proves efficacious in interposition of esophageal substitutes.
More Related Videos
10:30Simultaneously Capturing Real-time Images in Two Emission Channels Using a Dual Camera Emission Splitting System: Applications to Cell Adhesion
Published on: September 4, 2013
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Related Concept Videos
Cable Subjected to Concentrated Loads
Endoscopic Procedures III: Video Capsule Endoscopy
Insulation Coordination
Cable Subjected to a Distributed Load
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...