Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Analysis of Measurement Errors in Passive Sampling of Porewater PCB Concentrations under Static and Periodically
Mehregan Jalalizadeh1, Upal Ghosh1
1Department of Chemical, Biochemical, and Environmental Engineering, University of Maryland Baltimore County , Baltimore, Maryland 21250, United States.
Abstract:
Although the field of passive sampling to measure freely dissolved concentrations in sediment porewater has been sufficiently advanced for organic compounds in the low- to midrange of hydrophobicity, in situ passive sampling of strongly hydrophobic polychlorinated biphenyls (PCBs) is still challenged by slow approach to equilibrium. Periodic vibration of polyethylene (PE) passive samplers during exposure has been previously shown to enhance the mass transfer of polycyclic aromatic hydrocarbons (PAHs) from sediment into PE. Herein, we used a new vibrating platform, developed based on our earlier platform design, to demonstrate the effectiveness of periodic vibration for strongly hydrophobic compounds such as hexa-, hepta-, and octachloro-PCBs. Uptake of PCBs in PE after 7, 14, 28, and 56 days under different vibration modes was compared to that under static and mixed laboratory deployments. All PCBs reached within 95-100% of equilibrium after 56 days of deployment in the system vibrated briefly every 2 min, while none of the congeners achieved more than 50% of equilibrium in static deployment for the same period. Periodic vibration also increased the dissipation rate of four performance reference compounds (PRCs) from passive samplers. Higher fractional loss of PRCs and closer approach to equilibrium in the vibrated deployment resulted in estimation of corrected porewater concentrations that were statistically indistinguishable from the true equilibrium values even after a short 7-day deployment. Porewater concentrations of the strongly hydrophobic PCB congeners were overestimated by up to an order of magnitude in the static passive sampler after the same deployment time.
More Related Videos
11:43Dissolved Solute Sampling Across an Oxic-Anoxic Soil-Water Interface Using Microdialysis Profilers
Published on: March 24, 2023
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016
Related Concept Videos
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Voltammetry: Factors Affecting Measurements