Related Experiment Video
Updated: Mar 1, 2026

Surgical Technique for the Implantation of Tissue Engineered Vascular Grafts and Subsequent In Vivo Monitoring
Published on: April 3, 2015
Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection
Róbert Novotný1,2, Jaroslav Hlubocký1,2, Tomáš Kovárník2,3
12nd Surgical Clinic of Cardiovascular Surgery, General Teaching Hospital, Prague, Czech Republic.
Abstract:
We are presenting a case report of failed valve-in-valve treatment of severe aortic stenosis. A control ultrasonography after TAVI implantation revealed a severe aortic regurgitation of the graft which was subsequently unresolved with postimplantation dilatation. Second TAVI was implanted with cranial dislocation to the aortic root. Patient underwent a CT examination to clarify the TAVI in TAVI position. Patient underwent a surgical resection of TAVI with implantation of biological aortic valve prosthesis. In situations where TAVI treatment fails or is complicated beyond the possibility of endovascular repair, surgical intervention despite its higher risks is the preferred choice.