Related Experiment Video
Updated: Mar 1, 2026

Treating Low Back Pain in Failed Back Surgery Patients with Multicolumn-lead Spinal Cord Stimulation
Published on: June 26, 2018
Burst or High-Frequency (10 kHz) Spinal Cord Stimulation in Failed Back Surgery Syndrome Patients With Predominant
Sajjad Muhammad1, Sandra Roeske2, Shafqat Rasul Chaudhry1
1Department of Neurosurgery, Rheinische Friedrich Wilhelms University Hospital, Bonn, Germany.
Objectives:
Burst and 10 kHz spinal cord stimulation (SCS) demonstrated improvement for failed back surgery syndrome (FBSS) with predominant, refractory back pain. Here, we report the long-term follow-up of a previously published study comparing the safety and efficacy of burst vs. 10 kHz SCS for predominant back pain (70% of global pain) of FBSS patients.
Methods:
This comparative, observational study extended the follow-up period up to 20 months evaluating both SCS modalities. Pain intensity (visual analog scale [VASB , VASL ]), functional capacity (Pittsburgh Sleep Quality Index [PSQI]; depression (Beck Depression Inventory [BDI]), stimulation parameters and hardware and/or stimulation associated adverse events were recorded and analyzed over time.
Results:
Overall VASB (t1,12 = 66.76, p < 0.001) and VASL (t1,12 = 4.763, p < 0.049; p < 0.001) declined over time. Burst significantly decreased VASB by 87.5% (±17.7) (mean 8 ± 0.76 to 1 ± 1.41; t1 =12.3, p < 0.001), and 10 kHz significant decreased VASB by 54.9% (±44) (mean 8 ± 0.63 to 3.5 ± 3.27; t1 =3.09, p = 0.027). No significant differences for between SCS types were revealed (t1 =1.75, p = 0.13). VASL was significantly suppressed for burst (burst: 3.6 ± 1.59 to 1.5 ± 1.06; t1 = 3.32, p = 0.013). A significant effect of time was found for functional outcome with no significant differences between SCS types (PSQI: t1,12 = 8.8, p = 0.012; and BDI: t1 = 53.3, p < 0.001). No stimulation/hardware-related complications occurred.
Discussion:
Long-term data of this comparative study suggests that burst responsiveness was superior to 10 kHz in our small-scale cohort, thus a larger, randomized-controlled comparative study design is highly recommended.