Related Experiment Video
Updated: Mar 1, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Digital Imaging and Communications in Medicine (DICOM) information conversion procedure for SUV calculation of PET
Han-Back Shin1, Heesoon Sheen2, Ho-Young Lee3
1Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
Purpose:
In nuclear medicine, the standardized uptake value (SUV) obtained using positron emission tomography with 2-deoxy-2-fluoro-D-glucose (FDG-PET) is widely used as a semi-quantitative diagnosis factor. We found that the header file of the Philips Allegro PET scanner using the Digital Imaging and Communications in Medicine (DICOM) standard was stored differently than with other scanners. Thus, the purpose of this study was to develop a DICOM header information conversion program to ensure compatibility between Allegro and other equipment.
Methods And Results:
The NEMA IEC Body phantom was scanned using the Allegro PET scanner. We conducted measurements and performed calculations by using commercial software and the proposed self-developed program, respectively, to compare the SUVs by using conversion data. The program consists of three parts: an input part that can load data regardless of the number of DICOM images, and conversion and output parts that can be used to convert the DICOM header information and store it in the order of slices. The results of the calculation are in good agreement with the data measured at 12 circular regions of interest. The percent difference was lower than the 20%.
Conclusion:
In conclusion, this study suggested a simple and convenient method to solve the incompatibility through conversion of the DICOM header information. This study thus provides physicians more accurate information for diagnosis and treatment.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...