Related Experiment Video
Updated: Mar 1, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice
Diana L Miglioretti1, Laura Ichikawa2, Robert A Smith3
1Division of Biostatistics, Department of Public Health Sciences, University of California Davis School of Medicine, One Shields Ave., Med Sci 1C, Room 145, Davis, CA 95616; Kaiser Permanente Washington Health Research Institute, Seattle, Washington.
Rationale And Objectives:
Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set.
Materials And Methods:
This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated.
Results:
For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant.
Conclusions:
Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect.
More Related Videos
Related Concept Videos
Receiver Operating Characteristic Plot
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Drug Product Performance: In Vitro–In Vivo Correlation
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Spearman's Rank Correlation Test
Spearman's test calculates correlation by...

