Optical Coherence Tomography Reveals Changes to Corneal Reflectivity and Thickness in Individuals with Tear
Laura Adelaide Deinema1, Algis Jonas Vingrys1, Holly Rose Chinnery1
1Department of Optometry and Vision Sciences, Faculty of Medicine, Dentistry & Health Sciences, The University of Melbourne, Parkville, Victoria, Australia 3010.
Purpose:
To investigate whether tear hyperosmolarity, a feature of dry eye disease (DED), affects central corneal thickness (CCT), corneal light reflectivity, and/or tear film reflectivity.
Methods:
This prospective, cross-sectional study involved 48 participants (38 with hyperosmolar tears and 10 controls with normo-osmolar tears). Symptoms and signs of DED (tear osmolarity, sodium fluorescein tear break-up time, ocular surface staining, Schirmer test) were assessed. CCT, and the reflectivity of the cornea and the tear-epithelial interface were quantified relative to background noise using Fourier-domain optical coherence tomography (FD-OCT).
Results:
CCT of eyes with severe tear hyperosmolarity, defined as eyes in the upper quartile of the hyperosmolar group, was less than control eyes (539.1 ± 7.4 vs. 583.1 ± 15.0 μm, P = 0.02) and eyes with less severe tear hyperosmolarity, defined as hyperosmolar eyes in the lower quartile (622.7 ± 5.8 μm, P < 0.0001). CCT showed a negative linear relationship with tear osmolarity for values above 316 mOsmol/L (R2 = 0.17, P = 0.01). Central corneal reflectivity was lower in hyperosmolar eyes than normo-osmolar eyes (45.1 ± 0.3 vs. 48.1 ± 0.6 pixels, P = 0.02); the greatest relative difference was in the anterior stroma, where corneal reflectivity was 4.7 ± 1.9% less in hyperosmolar eyes (P < 0.01). Peak reflectivity of the tear-epithelial interface was 4.8% ± 3.5% higher in the hyperosmolar group than the normo-osmolar tear group (P = 0.04).
Conclusion:
Individuals with significant tear hyperosmolarity and clinical signs of symptoms of DED show reduced CCT and altered corneal reflectivity.
Translational Relevance:
Anterior segment FD-OCT provides novel insight into corneal microstructural differences in individuals with DED.