Related Experiment Video
Updated: Mar 1, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
High-flow nasal cannulae for respiratory support in adult intensive care patients
Amanda Corley1,2, Claire M Rickard2, Leanne M Aitken2,3,4
1Critical Care Research Group, The Prince Charles Hospital and University of Queensland, Level 5, CSB, Rode Rd, Chermside, Queensland, Australia, 4032.
Background:
High-flow nasal cannulae (HFNC) deliver high flows of blended humidified air and oxygen via wide-bore nasal cannulae and may be useful in providing respiratory support for adult patients experiencing acute respiratory failure in the intensive care unit (ICU).
Objectives:
We evaluated studies that included participants 16 years of age and older who were admitted to the ICU and required treatment with HFNC. We assessed the safety and efficacy of HFNC compared with comparator interventions in terms of treatment failure, mortality, adverse events, duration of respiratory support, hospital and ICU length of stay, respiratory effects, patient-reported outcomes, and costs of treatment.
Search Methods:
We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 3), MEDLINE, the Cumulative Index to Nursing and Allied Health Literature (CINAHL), Embase, Web of Science, proceedings from four conferences, and clinical trials registries; and we handsearched reference lists of relevant studies. We conducted searches from January 2000 to March 2016 and reran the searches in December 2016. We added four new studies of potential interest to a list of 'Studies awaiting classification' and will incorporate them into formal review findings during the review update.
Selection Criteria:
We included randomized controlled studies with a parallel or cross-over design comparing HFNC use in adult ICU patients versus other forms of non-invasive respiratory support (low-flow oxygen via nasal cannulae or mask, continuous positive airway pressure (CPAP), and bilevel positive airway pressure (BiPAP)).
Data Collection And Analysis:
Two review authors independently assessed studies for inclusion, extracted data, and assessed risk of bias.
Main Results:
We included 11 studies with 1972 participants. Participants in six studies had respiratory failure, and in five studies required oxygen therapy after extubation. Ten studies compared HFNC versus low-flow oxygen devices; one of these also compared HFNC versus CPAP, and another compared HFNC versus BiPAP alone. Most studies reported randomization and allocation concealment inadequately and provided inconsistent details of outcome assessor blinding. We did not combine data for CPAP and BiPAP comparisons with data for low-flow oxygen devices; study data were insufficient for separate analysis of CPAP and BiPAP for most outcomes. For the primary outcomes of treatment failure (1066 participants; six studies) and mortality (755 participants; three studies), investigators found no differences between HFNC and low-flow oxygen therapies (risk ratio (RR), Mantel-Haenszel (MH), random-effects 0.79, 95% confidence interval (CI) 0.49 to 1.27; and RR, MH, random-effects 0.63, 95% CI 0.38 to 1.06, respectively). We used the GRADE approach to downgrade the certainty of this evidence to low because of study risks of bias and different participant indications. Reported adverse events included nosocomial pneumonia, oxygen desaturation, visits to general practitioner for respiratory complications, pneumothorax, acute pseudo-obstruction, cardiac dysrhythmia, septic shock, and cardiorespiratory arrest. However, single studies reported adverse events, and we could not combine these findings; one study reported fewer episodes of oxygen desaturation with HFNC but no differences in all other reported adverse events. We downgraded the certainty of evidence for adverse events to low because of limited data. Researchers noted no differences in ICU length of stay (mean difference (MD), inverse variance (IV), random-effects 0.15, 95% CI -0.03 to 0.34; four studies; 770 participants), and we downgraded quality to low because of study risks of bias and different participant indications. We found no differences in oxygenation variables: partial pressure of arterial oxygen (PaO2)/fraction of inspired oxygen (FiO2) (MD, IV, random-effects 7.31, 95% CI -23.69 to 41.31; four studies; 510 participants); PaO2 (MD, IV, random-effects 2.79, 95% CI -5.47 to 11.05; three studies; 355 participants); and oxygen saturation (SpO2) up to 24 hours (MD, IV, random-effects 0.72, 95% CI -0.73 to 2.17; four studies; 512 participants). Data from two studies showed that oxygen saturation measured after 24 hours was improved among those treated with HFNC (MD, IV, random-effects 1.28, 95% CI 0.02 to 2.55; 445 participants), but this difference was small and was not clinically significant. Along with concern about risks of bias and differences in participant indications, review authors noted a high level of unexplained statistical heterogeneity in oxygenation effect estimates, and we downgraded the quality of evidence to very low. Meta-analysis of three comparable studies showed no differences in carbon dioxide clearance among those treated with HFNC (MD, IV, random-effects -0.75, 95% CI -2.04 to 0.55; three studies; 590 participants). Two studies reported no differences in atelectasis; we did not combine these findings. Data from six studies (867 participants) comparing HFNC versus low-flow oxygen showed no differences in respiratory rates up to 24 hours according to type of oxygen delivery device (MD, IV, random-effects -1.51, 95% CI -3.36 to 0.35), and no difference after 24 hours (MD, IV, random-effects -2.71, 95% CI -7.12 to 1.70; two studies; 445 participants). Improvement in respiratory rates when HFNC was compared with CPAP or BiPAP was not clinically important (MD, IV, random-effects -0.89, 95% CI -1.74 to -0.05; two studies; 834 participants). Results showed no differences in patient-reported measures of comfort according to oxygen delivery devices in the short term (MD, IV, random-effects 0.14, 95% CI -0.65 to 0.93; three studies; 462 participants) and in the long term (MD, IV, random-effects -0.36, 95% CI -3.70 to 2.98; two studies; 445 participants); we downgraded the certainty of this evidence to low. Six studies measured dyspnoea on incomparable scales, yielding inconsistent study data. No study in this review provided data on positive end-expiratory pressure measured at the pharyngeal level, work of breathing, or cost comparisons of treatment.
Authors' Conclusions:
We were unable to demonstrate whether HFNC was a more effective or safe oxygen delivery device compared with other oxygenation devices in adult ICU patients. Meta-analysis could be performed for few studies for each outcome, and data for comparisons with CPAP or BiPAP were very limited. In addition, we identified some risks of bias among included studies, differences in patient groups, and high levels of statistical heterogeneity for some outcomes, leading to uncertainty regarding the results of our analysis. Consequently, evidence is insufficient to show whether HFNC provides safe and efficacious respiratory support for adult ICU patients.
More Related Videos
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...

