Dose-dependence of transient respiratory motion artifacts on gadoxetic acid-enhanced arterial phase MR images
Hiroyuki Morisaka1,2, Utaroh Motosugi1, Shintaro Ichikawa1
1Department of Radiology, University of Yamanashi, Shimokato, Chuo-shi, Yamanashi, Japan.
Purpose:
To compare the occurrence of transient respiratory motion (TM) artifacts between 0.05 mmol/kg and 0.025 mmol/kg gadoxetic-acid on arterial phase MRI intra-individually for evaluating dose-dependence of gadoxetic acid.
Materials And Methods:
This retrospective study involved 91 patients who underwent dynamic MRI at 1.5T at different times, one time with 0.05 mmol/kg and the other 0.025 mmol/kg gadoxetic-acid. Examinations with 0.05 mmol/kg totaled 91 scans, and examinations with 0.025 mmol/kg totaled 375 scans (due to multiple exams for several patients). The scan with 0.025 mmol/kg closest in time to the 0.05 mmol/kg scan was selected to minimize temporal effects. Two radiologists graded TM artifacts in the arterial phase images using a four-point scale: no, mild, moderate, and severe artifacts. Results were compared between the two protocols (0.05 mmol/kg versus all 0.025 mmol/kg and 0.05 mmol/kg versus selected 0.025 mmol/kg), and the odds ratio for moderate-to-severe artifacts was calculated.
Results:
Significantly more TM artifacts were observed in the double dose (16/91 [17%]) scans compared with either all (17/375 [4%]; P < 0.01) or selected (3/91 [3%]; P = 0.01) standard dose scans. The odds ratio of the moderate-to-severe artifacts with the higher dose was 4.99-5.33.
Conclusion:
There appears to be dose-dependence of gadoxetic-acid and the occurrence of TM artifacts.
Level Of Evidence:
3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:433-438.
Insights
Higher doses of gadoxetic acid increase transient respiratory motion (TM) artifacts during arterial phase MRI. This study found a significant dose-dependence, with a nearly five-fold increased risk of moderate-to-severe artifacts at the higher dose.
Area of Science:
- Radiology
- Medical Imaging
- Pharmacology
Background:
- Transient respiratory motion (TM) artifacts can degrade image quality in dynamic MRI.
- Gadoxetic acid is a contrast agent used in liver MRI.
- Understanding artifact causes is crucial for accurate diagnosis.
Purpose of the Study:
- To compare the incidence of TM artifacts between 0.05 mmol/kg and 0.025 mmol/kg gadoxetic acid doses.
- To evaluate the dose-dependence of gadoxetic acid on TM artifact occurrence during arterial phase MRI.
- To assess the intra-individual impact of different gadoxetic acid concentrations on artifact levels.
Main Methods:
- Retrospective analysis of 91 patients undergoing dynamic 1.5T MRI.
- Comparison of scans with 0.05 mmol/kg versus 0.025 mmol/kg gadoxetic acid.
- Two radiologists graded TM artifacts on a four-point scale in arterial phase images.
Main Results:
- Significantly more TM artifacts occurred with the 0.05 mmol/kg dose (17%) compared to the 0.025 mmol/kg dose (4% or 3%).
- The odds ratio for moderate-to-severe artifacts was 4.99-5.33 with the higher gadoxetic acid dose.
- A clear dose-dependence of gadoxetic acid on TM artifact occurrence was observed.
Conclusions:
- Gadoxetic acid dose is directly related to the occurrence of transient respiratory motion artifacts.
- Lower doses of gadoxetic acid may reduce TM artifacts in arterial phase MRI.
- Optimizing contrast agent dosage can improve diagnostic accuracy in liver imaging.