Related Experiment Video
Updated: Mar 1, 2026

Assessment of Human Adipose Tissue Microvascular Function Using Videomicroscopy
Published on: September 29, 2017
Intra- and inter-day reproducibility of low-flow mediated constriction response in young adults
Michelle M Harbin1, Joseph D Ostrem1,2, Nicholas G Evanoff1
1Laboratory of Integrative Human Physiology, School of Kinesiology, University of Minnesota, Minneapolis, MN, USA.
Purpose:
When assessing brachial endothelial function by reactive hyperaemia, stopping blood flow creates a period of low-flow-mediated constriction (L-FMC). As little is known about how this parameter influences flow-mediated vasodilation (FMD), the purpose of this study was to better understand this relationship and to determine the intra- and interday reproducibility of brachial L-FMC.
Methods:
Brachial L-FMC and FMD were measured on 26 healthy, young adults (13 males, 13 females; 24·6 ± 2·7 years). Each participant had two assessments conducted on two separate visits, separated by a minimum of seven days. Brachial artery baseline diameter was imaged during rest. Continuous imaging of the artery was performed during the last 20 s of cuff-occlusion to 180 s postcuff release. An L-FMC was considered present if the relative change from pre-occlusion baseline to L-FMC artery diameter was less than -0·1%.
Results:
Overall, there was a strong, positive correlation between increased brachial L-FMC and blunted FMD (visit 1 test 1: r = 0·758, P<0·001; visit 1 test 2: r = 0·706, P<0·001; visit 2 test 1: r = 0·836, P<0·001; visit 2 test 2: r = 0·857, P<0·001). The reproducibility of intra- and interday L-FMC diameter was intraclass correlation coefficients (ICC) = 0·627, coefficient of variation (CV) = 54·4% and ICC = 0·734, CV = 43·5%, respectively.
Conclusion:
Vasoconstriction to low-flow conditions influences the subsequent maximal dilation during reactive hyperaemia. However, L-FMC is variable as evidenced by the weak intra- and interday reproducibility of the measure. Further research should study brachial L-FMC reproducibility among varying populations and the implications L-FMC has on the interpretation of FMD results.