Related Experiment Video
Updated: Mar 1, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Lung and Heart Dose Variability During Radiation Therapy of Non-Small Cell Lung Cancer
Nuzhat Jan1, Christopher Guy1, Leonid B Reshko1
1Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia.
Purpose:
To investigate the hypothesis that positional and anatomic variations during radiation therapy induce changes in lung and heart volumes and associated radiation doses.
Methods And Materials:
In this longitudinal investigation, variations in lung and heart volumes and standard dose parameters of mean lung dose, lung V20Gy, mean heart dose, and heart V40Gy were analyzed on weekly 4-dimensional CT scans of 15 lung cancer patients during conventionally fractionated radiochemotherapy. Tumor, individual lung lobes, and heart were delineated on the mid-ventilation phase of weekly 4-dimensional CT scans. Lung lobes and heart were also contoured on individual breathing phases of pre-, mid-, and end-of-treatment scans. Planning dose was transferred to consecutive scans via rigid registration. Volume and dose variations were assessed relative to the initial planning scan.
Results:
Interfraction lung volume variability relative to week 0 was twice as large as tidal volume variability (8.0% ± 5.3% vs 4.0% ± 3.3%, P=.003). Interfraction lung volume variation ranged between 0.8% and 17.1% for individual patient means. Lower lung lobes had larger volume variability compared with upper lobes (13.5% ± 8.1% vs 7.0% ± 5.0%, P<.00001). Average mean lung dose variation was 0.5 Gy (range, 0.2-1.0 Gy for individual patient means) and average lung V20Gy variation 0.9% (range, 0.2%-1.6%). Average heart volume variation was 7.2% (range, 3.4%-12.6%). Average mean heart dose variation was 1.2 Gy (range, 0.1-3.0 Gy) and average heart V40Gy variation 1.4% (range, 0%-4.2%).
Conclusions:
Anatomic and positional variations during radiation therapy induce changes in radiation doses to lung and heart. Repeated lung and heart dose assessment will provide a better estimate of the actual delivered dose and will improve prediction models for normal tissue toxicity, if assessed in larger cohorts.
Related Concept Videos
Dosage Regimen: Individualization
Dose Size and Dosing Frequency: Determination Methods
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant