Related Experiment Video
Updated: Mar 1, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Evaluating the effect of rectal distension on prostate multiparametric MRI image quality
Iztok Caglic1, Nienke L Hansen2, Rhys A Slough1
1Department of Radiology, Addenbrooke's Hospital and University of Cambridge, Cambridge, UK.
Purpose:
To evaluate the effect of rectal distension on the quality of anatomical and functional prostate multiparametric (mp) MRI.
Materials And Methods:
Multiparametric (mp) 3T-MRI images of 173 patients were independently evaluated by two radiologists in this retrospective study. Planimetry rectal volumes were derived and a subjective assessment of rectal distension was made using a 5-point Likert scale (1=no stool/gas, 5=large amount of stool/gas). Image quality of diffusion-weighted imaging (DWI) was evaluated using a 5-point Likert scale. DWI was further scored for distortion and artefact. T2W images were evaluated for image sharpness and the presence of motion artefact. The stability of the dynamic contrast-enhancement acquisition was assessed by recording the number of corrupt data points during the wash-out phase.
Results:
There was a strong correlation between subjective scoring of rectal loading and objectively measured rectal volume (r=0.82), p<0.001. A significant correlation was shown between increased rectal distension and both reduced DW image quality (r=-0.628, p<0.001), and increased DW image distortion (r=0.814, p<0.001). There was also a significant trend for rectal distension to increase artefact at DWI (r=0.154, p=0.042). Increased rectal distension led to increased motion artefact on T2 (p=0.0096), but did not have a significant effect on T2-sharpness (p=0.0638). There was no relationship between rectal distension and DCE image quality (p=0.693). 63 patients underwent lesion-targeted biopsy post MRI, there was a trend to higher positive predictive values in patients with minor rectal distension (34/38, 89.5%) compared to those with moderate/marked distension (18/25, 72%), p=0.09.
Conclusion:
Rectal distension has a significant negative effect on the quality of both T2W and DW images. Consideration should therefore be given to bowel preparation prior to prostate mpMRI to optimise image quality.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging