Related Experiment Video
Updated: Mar 1, 2026

Author Spotlight: Advancements and Challenges in Hepatitis B Virus Detection
Published on: December 15, 2023
[Loop-mediated isothermal amplification technique in the diagnosis of hepatitis B virus infection: a Meta-analysis]
1Key Laboratory for Medical Virology, National Health and Family Planning Commission, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
Abstract:
Objective: To evaluate the diagnostic performance of Loop-mediated isothermal amplification (LAMP) in the diagnosis of Hepatitis B Virus (HBV) infection using Meta-analysis. Methods: Literatures about LAMP in the diagnosis of HBV throughPubMed database of the National Library of Medicine, the EMBASE database of the Dutch Medical Digest, the Cochrane Clinical Trials Database, China Science Periodical Database, CSPD and the China National Knowledge Infrastructure (CNKI) were searched from 2000 to 2016, and the Language limited to Chinese and English. English search terms include: LAMP, Loop-mediated isothermal amplification, HBV, hepatitis B virus; Chinese search terms include: loop-mediated isothermal amplification technology, HBV, hepatitis B virus. The keywords and free words are combined to search the literature, and the references mentioned in the retrieval literature are searched twice. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR), Q index as well as area under summary receiver operating characteristic curve (SROC) were calculated with Stata 12.0 software. Results: A total of 12 literatures with 1 494 cases were included. The pooled sensitivity, specificity, positive likelihood ratio and negative likelihood ratio were 0.922 (95%CI: 0.905-0.937), 0.860 (95%CI: 0.818-0.896), 0.093 (95%CI: 0.048-0.182), and 15.400 (95%CI: 2.003-118.380), respectively. The DOR, area under SROC and Q index were 311.090 (95%CI: 95.841-1 009.800), 0.986 (95%CI: 0.974-0.998) and 0.949 (95%CI: 0.922-0.976), respectively. Deek's test indicates that no publication bias were found (P=0.140). Conclusion: LAMP is worth to be popularized in field tests and primary-level hospitals tests.
More Related Videos
11:14Detection of Low Copy Number Integrated Viral DNA Formed by In Vitro Hepatitis B Infection
Published on: November 7, 2018
11:34A Competent Hepatocyte Model Examining Hepatitis B Virus Entry through Sodium Taurocholate Cotransporting Polypeptide as a Therapeutic Target
Published on: May 10, 2022