Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
Introducing Cobalt(II) Porphyrin/Cobalt(III) Corrole Containing Transducers for Improved Potential Reproducibility
Ewa Jaworska1, Mario L Naitana2, Emilia Stelmach1
1Faculty of Chemistry, University of Warsaw , Pasteura 1, 02-093 Warsaw, Poland.
Abstract:
A novel solid contact type for all-solid-state ion-selective electrodes is introduced, yielding high stability and reproducibility of potential readings between sensors as well as improved analytical performance. The transducer phase herein proposed takes advantage of the presence of porphyrinoids containing the same metal ion at different oxidation states. In contrast to the traditional approach, the compounds of choice are not a redox pair; although they have different oxidation states, they cannot be electrochemically driven one to another. The compounds of choice were cobalt(II) porphyrin and cobalt(III) corrole-both characterized by a high stability of the coordinated metal ions in their respective redox states and electrical neutrality, as well as relatively high lipophilicity. The porphyrinoids were used together with carbon nanotubes to yield transducer layers for ion-selective electrodes. As a result, we obtained a high stability of potential readings of the resulting ion-selective electrodes together with good reproducibility between different sensor batches. Moreover, advantageously the presence of porphyrinoids in the transducer phase results in improvement of the analytical performance of the sensors: linear response range and selectivity due to interactions with membrane components, resulting in tailoring of ion fluxes through the membrane phase. Thus, carbon nanotubes with the cobalt(II) porphyrin/cobalt(III) corrole system are promising alternatives for existing transducer systems for potentiometric sensors.
More Related Videos
09:36In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
Published on: September 12, 2018
06:53Author Spotlight: Magnetometric Characterization of Intermediates in the Solid-State Electrochemistry of Redox-Active Metal-Organic Frameworks
Published on: June 9, 2023
Related Concept Videos
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Membrane Electrodes
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Electrochemical Cells
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...