Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

14.8K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
14.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Synchrotron-Based Deep Learning Network of the Inner Ear: Development and Expert Validation.

The Laryngoscope·2026
Same author

The cochlear morphometry compendium: High-resolution synchrotron measurements and normative reference values.

Journal of anatomy·2026
Same author

The tympanic covering layer contributes to basilar membrane elasticity potentially influencing human frequency resolution and speech perception.

Journal of anatomy·2026
Same author

Finite Element Modeling of Cochlear Mechanics: A Systematic Review.

Annals of biomedical engineering·2025
Same author

Statistical shape modeling of the human inner ear through micro-computed tomography imaging.

Anatomical record (Hoboken, N.J. : 2007)·2025
Same author

The Greenwood function shows close alignment with pitch perceived by cochlear implant patients with long, flexible electrode arrays and fine-structure stimulation.

Frontiers in neuroscience·2025

Related Experiment Video

Updated: Mar 1, 2026

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
03:58

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion

Published on: January 17, 2025

894

Evaluation of Cochlear Duct Length Computations Using Synchrotron Radiation Phase-Contrast Imaging.

Robert W Koch1, Mai Elfarnawany, Ning Zhu

  • 1*Biomedical Engineering Graduate Program†Department of Otolaryngology-Head and Neck Surgery, Western University, London, Ontario‡Canadian Light Source Inc., Saskatoon, Saskatchewan§Department of Medical Biophysics||Department of Electrical and Computer Engineering, Western University, London, Ontario, Canada.

Otology & Neurotology : Official Publication of the American Otological Society, American Neurotology Society [And] European Academy of Otology and Neurotology
|June 9, 2017
PubMed
Summary
This summary is machine-generated.

New equations for cochlear duct length (CDL) estimation improve accuracy using computed tomography A-values. These advancements enhance preoperative planning for cochlear implant electrode selection and frequency mapping.

More Related Videos

Evaluation of Planar-Cell-Polarity Phenotypes in Ciliopathy Mouse Mutant Cochlea
07:07

Evaluation of Planar-Cell-Polarity Phenotypes in Ciliopathy Mouse Mutant Cochlea

Published on: February 21, 2016

11.0K
Imaging the Aging Cochlea with Light-Sheet Fluorescence Microscopy
05:27

Imaging the Aging Cochlea with Light-Sheet Fluorescence Microscopy

Published on: September 28, 2022

3.0K

Related Experiment Videos

Last Updated: Mar 1, 2026

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
03:58

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion

Published on: January 17, 2025

894
Evaluation of Planar-Cell-Polarity Phenotypes in Ciliopathy Mouse Mutant Cochlea
07:07

Evaluation of Planar-Cell-Polarity Phenotypes in Ciliopathy Mouse Mutant Cochlea

Published on: February 21, 2016

11.0K
Imaging the Aging Cochlea with Light-Sheet Fluorescence Microscopy
05:27

Imaging the Aging Cochlea with Light-Sheet Fluorescence Microscopy

Published on: September 28, 2022

3.0K

Area of Science:

  • Otolaryngology
  • Medical Imaging
  • Biomedical Engineering

Background:

  • Accurate cochlear duct length (CDL) estimation is crucial for cochlear implant surgery.
  • Existing equations relating computed tomography (CT) A-values to CDL have limitations.
  • Novel imaging techniques offer potential for improved CDL measurement.

Purpose of the Study:

  • To evaluate novel imaging techniques for CDL measurement.
  • To develop and validate new equations for estimating CDL from CT A-values.
  • To improve the accuracy of preoperative electrode selection and frequency mapping.

Main Methods:

  • Ten cadaveric temporal bones were scanned using synchrotron radiation phase-contrast imaging.
  • Reference CDL values were determined by precise landmarking on imaging slices.
  • New and existing CDL equations were compared against reference values.

Main Results:

  • Newly proposed equations for organ of Corti (OC) and lateral wall (LW) reduced CDL estimation errors.
  • The new OC equation decreased error from 6.2% to 5.1%; the new LW equation reduced error from 3.9% to 3.6%.
  • Bland-Altman analysis confirmed improved agreement and clinical relevance of the new equations.

Conclusions:

  • The proposed OC and LW equations offer more accurate CDL estimates from CT A-values.
  • These improved equations facilitate precise preoperative planning for cochlear implants.
  • Enhanced accuracy aids in customized frequency mapping and better patient outcomes.