Related Experiment Video
Updated: Feb 28, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Early Hemodynamic Results in Patients With Small Aortic Annulus After Aortic Valve Replacement
Pierre Olivier Dionne1, Frédéric Poulin, Denis Bouchard
1From the *Department of Surgery, Montreal Heart Institute, Université de Montréal, Montreal, QC Canada; and †Department of Cardiology, Hôpital Sacré-Coeur de Montréal, Montreal, QC Canada.
Objective:
Patients with a small aortic annulus (≤21 mm) have an increased risk of patient-prosthesis mismatch after valve replacement. The aim of this study was to compare the early hemodynamic performance of the balloon-expandable transaortic valve implantation Edwards system (SAPIEN) and the sutureless Perceval prostheses.
Methods:
Fifty patients underwent transcatheter aortic valve implantation, and 113 patients underwent sutureless aortic valve replacement. Mean ± SD aortic annulus diameter was 19.7 ± 1 mm, with no significant difference between groups. SAPIEN valve size was 23 mm in 40 patients (80%) and 26 mm in 10 patients (20%). Perceval valve size was small in 45 patients (40%), medium in 62 patients (55%), and large in 6 patients (5%). Transthoracic Doppler echocardiographic images were collected at baseline and before discharge.
Results:
There were no significant difference in predischarge effective orifice area (SAPIEN: 1.5 ± 0.5 cm and Perceval: 1.48 ± 0.34 cm, P = 0.58) and indexed effective orifice areas (SAPIEN: 0.93 ± 0.32 cm/m and Perceval: 0.88 ± 0.22 cm/m, P = 0.42). Predischarge mean ± SD transaortic gradient was lower with the SAPIEN than with Perceval valves (12 ± 6 and 17 ± 6 mm Hg, respectively, P < 0.001). Rates of moderate and severe prosthesis-patient mismatch were similar (SAPIEN: 44% and 10% and Perceval: 50% and 14%, P = 0.53 and 0.75, respectively). There were no moderate-severe paravalvular leaks.
Conclusions:
Although indexed effective orifice areas were similar, transcatheter aortic valve implantation with the balloon-expandable SAPIEN system yielded lower predischarge transaortic mean gradients than the surgically implanted Perceval, in patients with a small annulus.
More Related Videos
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management
Aortic Regurgitation I: Introduction
Aortic Regurgitation IV: Nursing Management
Aneurysm IV: Nursing Management